TDS210: Difference between revisions
Jump to navigation
Jump to search
Jaredcabot (talk | contribs) (Added manual link) |
No edit summary |
||
Line 37: | Line 37: | ||
* Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak | * Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak | ||
* Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture | * Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture | ||
* Waveform Storage | * Waveform Storage: Two 2,500 point reference waveforms | ||
* Setups: 5 front panel setups | * Setups: 5 front panel setups | ||
* Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V | * Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V | ||
Line 44: | Line 44: | ||
* Backlit monochrome LCD with adjustable multilevel contrast | * Backlit monochrome LCD with adjustable multilevel contrast | ||
* Persistence: Off, 1 sec, 2 sec, 5 sec, infinite | * Persistence: Off, 1 sec, 2 sec, 5 sec, infinite | ||
* X-Y mode | * X-Y mode | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} |
Revision as of 05:34, 20 April 2023
The Tektronix TDS210 is a portable two-channel digital scope with 1 GS/s sampling rate and 60 MHz bandwidth.
Sister models include TDS220 (100 MHz dual-channel) and TDS224 (100 MHz quad-channel) .
Key Specifications
Bandwidth | 60 MHz (20 MHz at 2 mV/Div and 5 mV/Div, 20 MHz at 10 mV/Div in Peak Detect mode) |
---|---|
Sampling rate | 1 GS/s |
Sweep | 5 ns/Div to 5 s/Div |
Record Length | 2,500 sample points per channel |
Deflection | 2 mV/Div to 5 V/Div, 1-2-5 |
Resolution | 8 bit (256 levels over 10.24 vertical divisions) |
Features |
|
Software
- Waveform Converter For Oscilloscopes 066-0002-00 (ZIP)
- File Transfer Utility From TDS Scope To PC 066-0104-00 (ZIP)
- TDS200 series waveform transfer Mac as ASCII - 066-0106-00 (ZIP)
- TDS200 series 2XX sample RS232 program - 066-0108-00 (ZIP)
- DOS program to display FFT - 066-0109-00 (ZIP)
- WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00 (ZIP)
- Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00 (ZIP)
- Example Program To Get Crossing Levels 066-0178-00 (ZIP)
- TDS ISF File To CSV File Conversion Utility 066-0179-00 (ZIP)
- Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00 (ZIP)
- TDS Waveform Logging Sample Program 066-0194-00 (ZIP)
- Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00 (ZIP)
- Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00 (ZIP)
- Transfer Setups Between TDS Oscilloscopes 066-0198-00 (ZIP)
- VB Program To Capture TDS Extended Waveforms 066-0200-00 (ZIP)
- Wavestar for Oscilloscopes V3.0.0 - 066-0934-03 (ZIP) (105 Mb)
- TekVISA Connectivity Software V4.0.4 - 066-0938-09 (ZIP) (447 Mb)
- TekVISA Connectivity Software V4.1.1 - 066-0938-11 (ZIP) (101 Mb)
- TekVISA Connectivity Software V4.2.0 - 066-0938-12 (ZIP) (101 Mb)
- Openchoice Desktop Application V2.6 - 066-0939-14 (ZIP) (117 Mb)
- Openchoice Desktop Application V2.8 - 066-0939-15 (ZIP) (117 Mb)
Firmware
- TDS210-220 v1.06 Firmware - 163-0792-01 (ZIP)
- TDS210-220 v1.09 Firmware - 163-0792-02 (ZIP)
- TDS210-220 v1.16 Firmware - 163-0792-03 (ZIP)
- TDS210-220 v1.17 Firmware - 163-0792-04 (ZIP)
- TDS210-220 v1.19 Firmware - 163-0792-06 (ZIP)
Options
- TDS2HM Hard Copy module:
- Centronics parallel (printer)
- TDS2CM, TDS2CMA, TDS2CMAX Communications module:
- Centronics parallel (printer), RS-232 serial, GPIB
- TDS2MM Measurement Extension Module:
- Functions of TDS2CM plus:
- 2048-point FFT, with Hanning, Flat Top, Rectangular windows
- Automatic Measurements - Rise/fall time, positive/negative pulse width
Optional Accessories
- RM200 – Rack mount kit
- AC220 – Soft case
- HCTDS32 – Hard case
Links
- Loose BNC fix and Recall mod – Near Far Media @ YouTube
- Replacing LCD backlight CCFL tube – Near Far Media @ YouTube
Pictures
-
TDS210
-
Interface module
-
Front Cover Installed
-
TDS 220
-
TDS 220
-
TDS 220