2215: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (T940 CRT heater supply fix. Very similar to 045-0034-00)
Line 22: Line 22:
==Service Info==
==Service Info==
* [[Media:045-0034-00.pdf|CRT Power supply improvement 045-0034-00]]
* [[Media:045-0034-00.pdf|CRT Power supply improvement 045-0034-00]]
* [[Media:T940-letter-June-1983.pdf|CRT heater power supply modification]]
* [[Media:Tek_2200_PSU_Noise_Mod-54681.pdf|PSU Audible Noise Mod #54681]]
* [[Media:Tek_2200_PSU_Noise_Mod-54681.pdf|PSU Audible Noise Mod #54681]]
* [[Media:SUP3010.pdf|Tek Service Update Plan 3010, CRT filament voltage reduction]]
* [[Media:SUP3010.pdf|Tek Service Update Plan 3010, CRT filament voltage reduction]]

Revision as of 14:35, 30 April 2023

Manuals – Specifications – Links – Pictures

The Tektronix 2215 is a portable dual-trace 60 MHz scope from the 2000-series of low-cost analog scopes.

There are two revisions of the 2215, the major difference being in the power supply. Hence two service manuals.

There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)

Key Specifications

Deflection 2 mV/div to 10 V/div, 1-2-5
Rise time < 5.8 ns (calculated)
Bandwidth DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C
Input impedance 1 MΩ ±2% // 30 ±3 pF
Maximum Safe Input Voltage 400 V (DC + peak AC) or 800 Vp-p AC to 1 kHz or less
CMRR At least 10:1 at 10 MHz
Timebase 50 ns/Div to 500 ms/Div, 1-2-5,  ×10 magnifier, i.e. down to 5 ns/Div
Trigger sensitivity 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz; AC coupled ≥10 Hz
External trigger input max. 400 V (DC+peak AC) or 800 Vp-p AC to 1 kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF
Trigger modes Auto, Norm, TV Field
Z axis input (intensity); DC to 5 MHz
CRT display area : 80 × 100 mm²
Weight 6.1 kg; 7.6 kg with front panel cover, accessories and pouch
Dimensions With feet and handle: 137 x 361 x 511 mm³
Features
  • X-Y operation
  • Probe adjust (0.5V at 1kHz)

Links