Neon Lamps: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 40: | Line 40: | ||
|align="center"| 58 V | |align="center"| 58 V | ||
|align="center"| 0.3 mA | |align="center"| 0.3 mA | ||
|- | |||
| NE-2V | |||
| 150-030 | |||
|align="center"| 76 (60−90) V | |||
|align="center"| 58 (46-78) V | |||
|align="center"| 0.6 mA | |||
| short length, formed tip for end-on viewing, mild radioactive additive for the reduction of dark effect | |||
|- | |- | ||
| NE-23 | | NE-23 | ||
| | | 150-027 | ||
|align="center"| 74 (60−90) V | |align="center"| 74 (60−90) V | ||
|align="center"| 59 V | |align="center"| 59 V | ||
|align="center"| 0.3 mA | |align="center"| 0.3 mA | ||
| | | mild radioactive additive for reduction of dark effect | ||
|} | |} | ||
''Please add'' | ''Please add'' |
Revision as of 02:43, 6 June 2023
Neon lamps are used for at least three different things in Tek instruments:
- Indicator lamps, e.g., for power, beam position, uncalibrated status, or a decimal point
- Voltage clamp, similar to how a zener diode is used
- In relaxation oscillators, e.g. in 7000-series power supplies
Neon lamps fail more than most other components. A common failure mode is for the leads to break off, often close to the glass bulb, due to corrosion and vibration. Another failure mode is for the I-V characteristic to drift.
Neon lamps are used as a voltage clamp in the CRT circuit for setting the CRT grid voltage in many Tek instruments. A typical example is seen in the 561A:
If the neon lamps fail, the CRT grid voltage will be affected.
Another common use is for DC bias shifting, e.g. in 500-series timebase circuits.
When in doubt, replace the neon lamps. In a pinch, it may be possible to reattach broken leads after careful grinding of the glass.
Types and data
Type | Tek P/N | Voltage | Current | Notes | |
---|---|---|---|---|---|
Ignition | Operating | Nominal | |||
NE-2 | 150-002 | 76 (60−90) V | 58 V | 0.3 mA | |
NE-2V | 150-030 | 76 (60−90) V | 58 (46-78) V | 0.6 mA | short length, formed tip for end-on viewing, mild radioactive additive for the reduction of dark effect |
NE-23 | 150-027 | 74 (60−90) V | 59 V | 0.3 mA | mild radioactive additive for reduction of dark effect |
Please add