2236: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 26: | Line 26: | ||
The '''Tektronix 2236''' is a 100 MHz portable scope with a dual time base and a built-in DMM/counter with a dedicated 9-digit VF display. | The '''Tektronix 2236''' is a 100 MHz portable scope with a dual time base and a built-in DMM/counter with a dedicated 9-digit VF display. | ||
Apart from the counter, it is the same as the [[2235]]. | Apart from the counter, it is the same as the [[2235]]. | ||
An "A" model also exists. | |||
In addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase. | In addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase. | ||
Line 58: | Line 60: | ||
* [http://www.hakanh.com/dl/docs/hardtofind/2200_ps_noise.pdf Power Supply Audible Noise] | * [http://www.hakanh.com/dl/docs/hardtofind/2200_ps_noise.pdf Power Supply Audible Noise] | ||
== | ==2236== | ||
<gallery> | <gallery> | ||
Tek 2236 trace.jpg | 2236 trace | Tek 2236 trace.jpg | 2236 trace | ||
Line 73: | Line 75: | ||
2236(4).jpg | 2236(4).jpg | ||
2236(5).jpg | 2236(5).jpg | ||
</gallery> | |||
==2236A== | |||
<gallery> | |||
2236a.png | |||
</gallery> | </gallery> | ||
[[Category:2200 series scopes]] | [[Category:2200 series scopes]] |
Revision as of 13:40, 24 July 2023
The Tektronix 2236 is a 100 MHz portable scope with a dual time base and a built-in DMM/counter with a dedicated 9-digit VF display. Apart from the counter, it is the same as the 2235.
An "A" model also exists.
In addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase.
Key Specifications
Bandwidth | 90 MHz at 2 mV/Div, 100 MHz at 5 mV/Div and above; switchable 20 MHz limit |
---|---|
Rise time | 3.9 ns at 2 mV/Div, 3.5 ns at 5 mV/Div and above |
Deflection | 2 mV/Div to 5 V/Div, 1−2−5, ±2%, and variable 2.5:1 |
Time base | 50 ns/Div to 500 ms/Div (B timebase to 50 ms/Div), 1−2−5, ×10 magnifier for fastest deflection of 5 ns/Div |
Frequency counter | 7 digit resolution; frequency 100 Hz to 100 MHz in decade ranges, period 100 μs to 1 s in decade ranges, plus 5 s range; time base accuracy 1×10-5 (Opt.14: 5×10-7), sensitivity same as trigger specs |
Multimeter | 3¾ digit resolution, ≥2.5 measurements per second, 10 MΩ input resistance, input isolated from scope ground; DC volts 0.5 V to 500 V in decade ranges; AC volts RMS 0.5 V to 350 V in decade ranges; resistance 50 Ω to 50 MΩ in decade ranges, plus 200 MΩ and 2 GΩ ranges; temperature -62 °C to +230 °C (with P6602 probe) |
Input impedance | 1 MΩ // 20 pF |
Trigger sensitivity | 0.3 Div or 35 mV up to 10 MHz, 1 Div or 120 mV up to 60 MHz, 1.5 Div or 200 mV up to 100 MHz |
CRT | 80×100 mm² display area, P31 phosphor, 14 kV acceleration voltage |
Power | 90−250 VAC, 48 to 440 Hz, 40 W |
Size | 137 mm × 328 mm × 440 mm (5.4" × 12.9" × 17.3") |
Weight | 5.2 kg (11.5 lb) without accessories |
Features |
|
Prices
- 1984: $2,650 (2017 value: $6,240)
Links
2236
-
2236 trace
-
counter/DMM display
-
interior, right
-
interior, top
-
interior, left
-
funny face behind U1902 on the A12 board of Tek 2236
-
-