Timebase plug-in units with serial numbers listed below require modification [[040-0413-00]] to provide the sweep signal to the 3L5 (To pin 18 of the [[560_Series_plug-in_interface|plug-in connector]]). | Timebase plug-in units with serial numbers listed below require modification [[040-0413-00]] to provide the sweep signal to the 3L5 (To pin 18 of the [[560_Series_plug-in_interface|plug-in connector]]). |
Revision as of 01:04, 29 September 2023
The Tektronix 3L5 is a 50 Hz - 1 MHz spectrum analyzer plug-in for 560-series scopes. It is very similar to the 1L5.
In conjunction with the 015-0107-00 Swept Frequency Converter (tracking generator), the 3L5 can also be used to make scalar frequency response measurements.
A video filter switch was added to the later SNs (1971 Catalog). The 3L5 is based on the swept-frontend design, where the first local Oscillator is swept for the spectrum scan. It is a full semiconductor design except for the final output amplifier, which uses a 8416 vacuum tube.
75 Ω Version
There is also a 75 Ω version of the 3L5. Its input is on the rear, via a coaxial connector. A lever on the front panel switches between two frequency ranges:
- 10 kHz - 1 MHz
- 18.010 MHz - 19 MHz
Timebase Support
The 3L5 requires a timebase plug-in in the horizontal compartment to operate.
Timebase plug-in units with serial numbers listed below require modification 040-0413-00 to provide the sweep signal to the 3L5 (To pin 18 of the plug-in connector).
Time Base | SN# |
---|---|
2B67 | <15180 |
3B1 | <4040 |
3B3 | <4270 |
3B4 | <740 |
Key Specifications
Center Frequency | 50 Hz to 990 kHz |
---|---|
Dispersion | 10 Hz to 100 kHz |
Input Impedance | 1 MΩ // 30 pF |
Input Voltage | Max. 300 V (DC + peak AC) |
Vertical Resolution | Video - 100 mV/div to 100 V/div, LIN - 1 mV to 2 VRMS |
Internal Cal Signal | 5 kHz ±1% |
First LO Out | ≥1 MHz (Sweep), ≥1 Vp-p into ≥1 kΩ |
Recorder Out | 5 mV to 15 mV into 600 Ω |
Weight | 2.7 kg / 6 lbs |
Pictures
1 MΩ version
-
-
-
-
1 MΩ Version
-
1 MΩ later version with Video Filter Switch
-
LHS
-
RHS
-
Top
-
Bottom
-
Internals - 3 MHz Filter, 2nd LO (3.1 MHz) and 2nd mixer.
-
Internals - 3 MHzFilter, 2nd LO (3.1 MHz) and 2nd mixer.
-
Internals - 100 kHz crystal from variable res amp 158-0022-00
-
Internals - 100 kHz crystal from variable res amp 158-0022-00
75 Ω version
-
75 Ω version of 3L5, front
-
75 Ω version, front/top
-
75 Ω version, left
-
75 Ω version, top
-
75 Ω version, bottom left
-
75 Ω version
-
75 Ω version
-
75 Ω version, back
Components
Some Parts Used in the 3L5
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
1N3182 | 152-0269-00 | Discrete component | varactor diode | 3L5 • 1L5 • 3T7 • 492 • 465M • 7844 • 2465 |
8416 | 154-0413-00 • 157-0116-00 | Vacuum Tube (Dual Triode) | dual triode | 1S1 • 2A61 • 3A8 • 3L5 • W |