5223: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 38: Line 38:
==Links==
==Links==
* [[Media:Tekscope 1980 V12 N4.pdf  |  Vol. 12 No. 4, Dec 1980: Cliff Baker, ''Digital Storage and Plug-in Versatility Distinguish New 10-MHz 5000-Series Oscilloscope]]
* [[Media:Tekscope 1980 V12 N4.pdf  |  Vol. 12 No. 4, Dec 1980: Cliff Baker, ''Digital Storage and Plug-in Versatility Distinguish New 10-MHz 5000-Series Oscilloscope]]
* [https://www.youtube.com/watch?v=aw9YqKZTj90 Tektronix 5223 Digitizing Oscilloscope] @ Youtube – Tektronix film courtesy of the Vintage Tek Museum
* [https://www.youtube.com/watch?v=aw9YqKZTj90 Tektronix 5223 Digitizing Oscilloscope] @ Youtube – Tektronix promotional film, courtesy of the [https://vintagetek.org/ Vintage Tek Museum]


==Pictures==
==Pictures==

Revision as of 12:37, 6 October 2023

Tektronix 5223
10 MHz analog/digital mainframe
Tektronix 5223

Produced from 1981 to 1988

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 5223 is a 10 MHz mainframe with digital storage. The 5B25N timebase was designed for this scope to allow recording of pretrigger events. The scope is compatible with the faster 5A3x and 5A4x vertical plugins but does not provide on-screen readout.

When equipped with Option 10 (GPIB), some major parts of the internal control circuits were changed and the scope was called "5223 Option 10". There is a complete different set of user and service manual for this model.

Key Specifications

Bandwidth 10 MHz with 5A38, 5A45, 5A48; 12 MHz mainframe analog bandwidth, tested with 067-0680-00; X axis 7 MHz
Fastest cal. sweep 20 ns/Div
Sample rate up to 1 MS/s (1 vertical bay) / 500 kS/s (2 bays)
Resolution 10 bit
Memory 1k samples per vertical bay
CRT 8×10 Div @ 1.22 cm/Div, 15 kV acceleration, P31 phosphor 154-0827-00
Features
  • Roll mode
  • Recorder output
  • GPIB interface (Option 10)

Internals

The Opt.10 board uses a Zilog Z-80 processor.

Links

Pictures

ROM images