For measuring and calibrating luminance and chrominance waveform characteristics of video signal generators and waveform monitors. The VAC generates a precise square wave from its low impedance output with a resolution of 0.1mV and an accuracy of 0.05% from 0 to 999.9mV. Color standards for NTSC, PAL, PAL-M, and SECAM along with other signal parameters such as half or full amplitude and many others may be selected. 
It is used for measuring and calibrating luminance and chrominance waveform characteristics of video signal generators and waveform monitors.  


The 067-0916-00 came with a Subcarrier Harmonic Rejection Filter ([[015-0407-00]]), 0.6% attenuator ([[011-0134-00]]), and precision terminator ([[011-0102-01]]).
{{MissingSpecs}}
The VAC generates a precise square wave from its low impedance output with a resolution of 0.1 mV and an accuracy of 0.05% from 0 to 999.9 mV.
Color standards NTSC, PAL, PAL-M, and SECAM along with other signal parameters such as half or full amplitude and many others may be selected.


{{MissingSpecs}}
The 067-0916-00 came with a subcarrier harmonic rejection filter ([[015-0407-00]]), 0.6% attenuator ([[011-0134-00]]), and precision terminator ([[011-0102-01]]).
 
==Links==
* [[Media:ServiceTekNotes 20 Nov 1981.pdf|ServiceTekNotes Issue 20, Nov 1981 (pp.13+)]]


==Pictures==
==Pictures==

Revision as of 05:07, 14 November 2023

Tektronix 067-0916-00
video amplitude calibration fixture (VAC)
Tektronix 067-0916-00

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0916-00 is a video amplitude calibration fixture (VAC) plug-in for the TM500 system.

It is used for measuring and calibrating luminance and chrominance waveform characteristics of video signal generators and waveform monitors.

Key Specifications

  • please add

The VAC generates a precise square wave from its low impedance output with a resolution of 0.1 mV and an accuracy of 0.05% from 0 to 999.9 mV. Color standards NTSC, PAL, PAL-M, and SECAM along with other signal parameters such as half or full amplitude and many others may be selected.

The 067-0916-00 came with a subcarrier harmonic rejection filter (015-0407-00), 0.6% attenuator (011-0134-00), and precision terminator (011-0102-01).