P6021: Difference between revisions
No edit summary |
mNo edit summary |
||
Line 2: | Line 2: | ||
|manufacturer=Tektronix | |manufacturer=Tektronix | ||
|model=P6021 | |model=P6021 | ||
|summary= | |summary=oscilloscope current probe | ||
|image=Tek-p6021.jpg | |image=Tek-p6021.jpg | ||
|caption=P6021 with Passive Termination Box | |caption=P6021 with Passive Termination Box |
Latest revision as of 21:10, 2 December 2023
The Tektronix P6021 is a 125-turn AC current probe for oscilloscopes. It can be used with the included passive termination box (011-0105-00), a Type 134 Current Probe Amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in.
Bandwidth is up to 52 MHz.
The P6021 has a contact to short the ring around the 7A14's BNC input to ground, to switch frequency compensation and gain.
The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.
Specifications
P6021 + 011-0105-00 passive termination | P6021 + 134 | P6021 + 7A14 | P6022 + 011-0106-00 passive termination | P6022 + 134 | P6022 + 7A14 | |
---|---|---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/Div to 1 A/Div | 1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/Div to 1 A/Div |
Bandwidth (–3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 50 MHz | 200 MHz @ 10 mA/mV | > 70 MHz | 105 MHz |
LF limit (–3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 25 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz | 250 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |
Links
Documents Referencing P6021
- (no results)
Prices
Year | 1970 | 1974 | 1984 | 1986 | 1988 |
---|---|---|---|---|---|
Catalog price | $121 | $100 | $345 | $430 | $450 |
2021 value | $850 | $550 | $910 | $1,070 | $1,040 |
Pictures
-
Tektronix P6021 with the 011-0105-00 passive termination box
-
P6021 catalog image
-
P6021A
-
Schematic (click to enlarge)
Measurement examples
-
Measuring diode reverse recovery
-
Small-signal diode reverse recovery, 20 mA/Div
Comparison of P6022 with passive termination @ 10 mA/Div (top trace) vs. P6021+134 (bottom trace).
The signal shown is a sawtooth from a HP3325A @ 5 Vp-p into 50 Ω = 100 mAp-p.
-
100 Hz
-
1 kHz
-
10 kHz