067-0508-00: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (Capitolize sidebar summary)
No edit summary
 
Line 11: Line 11:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:Tek 067-0508-00.pdf|Tektronix 067-0508-00 Manual]] (PDF, OCR)
* [[Media:Tek 067-0508-00.pdf|Tektronix 067-0508-00 Manual]] (OCR)
* [[Media:Tek 067-0508-00 schematics.pdf|Tektronix 067-0508 Schematics]] (PDF)
* [[Media:Tek 067-0508-00 schematics.pdf|Tektronix 067-0508 Schematics]]
<!--
* [http://w140.com/tek_067_0508_00.pdf Tektronix 067-0508-00 Manual (PDF)]
-->
}}
}}
The '''Tektronix 067-0508-00''' Amplitude Calibrator generates a square-wave with two precisely controlled voltages and 50 Ω impedance at both voltages.
The '''Tektronix 067-0508-00''' Amplitude Calibrator generates a square-wave with two precisely controlled voltages and 50 Ω impedance at both voltages.


This could be achieved by a 50 Ω resistor in series with the output of an amplifier with 0 Ω output resistance (e.g., an opamp with plenty of negative feedback).  But that is not how Tektronix did it. 
The calibrator uses a 50 Ω shunt resistance at the output, and a precision DC current source that can be steered toward the output, or toward a dummy current sink transistor.   
They used a 50 Ω shunt resistance at the output, and a precision DC current source that can be steered toward the output or toward a dummy current sink transistor.   
The built-in multivibrator controls the steering of the current.   
The built-in multivibrator controls the steering of the current.   


The output is through a [[GR-874 connector]]. The [[067-0515-00|067-0515-00 precision 50 Ω terminator]]  
The output is through a [[GR-874 connector]]. The [[067-0515-00|067-0515-00 precision 50 Ω terminator]] is intended to be used with the 067-0508-00.
is intended to be used with the 067-0508-00.


==Pictures==
==Pictures==

Latest revision as of 03:32, 12 June 2024

Tektronix 067-0508-00
Amplitude Calibrator
Tektronix 067-0508-00

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0508-00 Amplitude Calibrator generates a square-wave with two precisely controlled voltages and 50 Ω impedance at both voltages.

The calibrator uses a 50 Ω shunt resistance at the output, and a precision DC current source that can be steered toward the output, or toward a dummy current sink transistor. The built-in multivibrator controls the steering of the current.

The output is through a GR-874 connector. The 067-0515-00 precision 50 Ω terminator is intended to be used with the 067-0508-00.

Pictures