P6015: Difference between revisions
No edit summary |
mNo edit summary |
||
Line 18: | Line 18: | ||
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model. | It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model. | ||
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. For this reason, | The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. For this reason, in 1991 the P6015 was replaced by the [[P6015A]], which uses a silicone-based dielectric. | ||
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with [[PL-259]] or [[BNC]] plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively). | The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with [[PL-259]] or [[BNC]] plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively). |
Latest revision as of 23:31, 20 November 2024
The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the P6013 predecessor model. The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. For this reason, in 1991 the P6015 was replaced by the P6015A, which uses a silicone-based dielectric.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with PL-259 or BNC plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively).
Key Specifications
Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) |
---|---|
Risetime | 4.67 ns (10' cable), 14 ns (25' cable) |
Attenuation | 1000× |
Input impedance | 100 MΩ // 3 pF |
Compensation range | 15-50 pF |
Max. input voltage |
|
Links
Documents Referencing P6015
- (no results)
Patents that may apply to P6015
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3256484A | High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein | Paul V Terry | 1962-09-10 | 1966-06-14 | P6015 |
Pictures
-
Tektronix P6015 in box
-
-
-
-
-
-
-
schematic
old version -
Derating curves
-
Can of Freon Dielectric Fluid
-
Termination box
new version