Neon Lamps
Neon lamps are used for at least three different things in Tek instruments:
- Indicator lamps, e.g., for power, beam position, or uncalibrated status
- Voltage clamp, similar to how a zener diode is used
- In relaxation oscillators, e.g. in 7000-series power supplies
Neon lamps fail more than most other components. A common failure mode is for the leads to break off, often close to the glass bulb, due to corrosion and vibration. Another failure mode is for the I-V characteristic to drift.
Neon lamps are used as a voltage clamp in the CRT circuit for setting the CRT grid voltage in many Tek instruments. A typical example is seen in the 561A:
If the neon lamps fail, the CRT grid voltage will be affected.
Another common use is for DC bias shifting, e.g. in 500-series timebase circuits.
When in doubt, replace the neon lamps. In a pinch, it may be possible to reattach broken leads after careful grinding of the glass.
Types and data
- NE-23 pls add data
- ...