P6022
The Tektronix P6022 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is at least 200 MHz with the passive termination.
The sister model P6021 has lower bandwidth but also a lower LF cut-off frequency and higher peak current rating.
Specifications
P6021 passive | P6021 + 134 | P6022 passive | P6022 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV 120 Hz @ 10 mA/mV |
< 12 Hz | 8500 Hz @ 1 mA/mV 935 Hz @ 10 mA/mV |
< 100 Hz |
Maximum current | 15 Ap-p | 6 Ap-p (> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz) |