7L13

Revision as of 04:25, 9 August 2021 by Peter (talk | contribs)


The Tektronix 7L13 is a 1 kHz to 1.8 GHz Spectrum Analyzer plug-in for 7000-series scopes. From 1977 on, a modified version with coverage up to 2.5 GHz was available upon request (no official option listed in the catalog).

Tektronix 7L13
1.8/2.5 GHz Spectrum Analyzer
Tektronix 7L13

Compatible with 7000-series scopes

Produced from 1974 to 1981

Manuals
(All manuals in PDF format unless noted otherwise)

It is similar to the 7L12 but occupies three module bays, adds a marker function, offers resolution bandwidth down to 30 Hz, and improves sensitivity by 10 dB. It also displays the center frequency in the CRT readout as well as on a LED display.

The TR502 tracking generator is designed to work with the 7L13 up to 1.8 GHz.

Key Specifications

Input frequency 100 kHz – 1.8 GHz (modified version up to 2.5 GHz)
Span 200 Hz/Div – 100 MHz/Div
Sweep 1 μs/Div to 10 s/Div (1−2−5), manual, external
Resolution bandwidth 30 Hz – 3 MHz in decade steps
Sensitivity −128 dBm at 300 Hz to −80 dBm at 3 MHz
Vertical scale 10 dB/Div, 2 dB/Div or linear
Reference level −110 dBm – +30 dBm in 10 dB steps
Video filters 30 kHz, 300 Hz or 10 Hz
Features
  • Automatic phase lock
  • CRT readout of center frequency
  • UNCAL indicator
  • built-in calibrator 50 MHz, −30 dBm
  • Base line clipper

Links

Prices

Year 1974 1976 1980
Catalog price $6,500 $7,500 $10,500
2020 Dollars $34,100 $34,100 $33,000

Internals

The input signal passes a 0 to 60 dB step attenuator, a 1.8 GHz low-pass filter, and a 3 dB isolation pad before the 1st mixer, with a 1st LO frequency between 2.095 GHz and 3.895 GHz. At spans of 50 kHz/Div and below, the 1st LO (a YIG oscillator) is fixed (stabilized by a PLL) and the 2nd LO is swept.

The 1st IF filter is 10 MHz wide, centered at 2.095 GHz. With a 2nd LO at 2.2 GHz, the signal is mixed to a 105 MHz IF, amplified, filtered again (105±1.5 MHz) and mixed down to 10 MHz (3rd LO at 95 MHz).

At the 10 MHz 3rd IF, resolution filters (300 kHz L/C, 30 kHz, 3 kHz or 300 Hz crystal filters) can be selected. The detector (discrete log amplifier) and video filters follow.

The digital frequency readout is a DVM (Fairchild 3814) working off the the YIG oscillator control voltage, not a frequency counter, which is why it needs to be calibrated before use.

Custom integrated circuits used: 155-0035-00 quad opamp, 155-0042-02 Miller integrator, 155-0056-00 sweep control, 155-0088-00 legend generator.

Pictures