P6033
The Tektronix P6033 (010-099, 010-0099-00) is a special probe designed to couple trigger signals to early sampling scopes (567, 661, 560 series samplers).
It achieves a 10:1 attenuation at a 1 kΩ:50 Ω impedance ratio through the use of a T-coil, foregoing LF and DC response.
Key Specifications
Attenuation | ×10 |
---|---|
Frequency range | 1.5 MHz to 300 MHz |
Rise time | 1.5 ns |
Delay | 10 ns |
Input impedance | 1 kΩ |
Output | to 50 Ω via GR-874 connector |
Maximum voltage | ±15 VDC or RMS, ±400 VDC when AC coupled |