3T4

Revision as of 10:41, 21 July 2023 by Kurt (talk | contribs)

The Tektronix Type 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.

Tektronix 3T4
Programmable Sampling Sweep
3T4 sweep unit

Compatible with 560-series scopes

Produced from 1965 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)

Specifications

The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. The maximum trigger frequency is 1 GHz.

The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.

The remotely programmable functions are

  • Equivalent-time sweep rate
  • Delay time
  • Samples per sweep
  • Normal or single-display mode
  • Single-display start

See Also

Pictures


Some Parts Used in the 3T4

Part Part Number(s) Class Description Used in
8056 154-0417-00 Vacuum Tube (Triode) low-voltage Nuvistor triode 422 502 W 1S1 3A7 3S3 3T4 5T3 10A1