P6041
The Tektronix P6041 is an AC current probe for oscilloscopes.
The CT-2 is the current transformer part of the probe. It was designed by Murlan Kaufman. Multiple CT-2 units can be left installed in a circuit and only one connected using the P6041 cable.
Key Specifications
Bandwidth | "30% down at 1.2 kHz, 7% down at 200 MHz" |
---|---|
Sensitivity | 1 mV/mA into a 50 Ω load |
Current range | max. 2.5 ARMS, 100 A peak |
Links
Documents Referencing P6041
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1971 V3 N5 Sep 1971.pdf | Article | The 7D14 Counts Current to Minimize Circuit Loading | Emory Harry | 1971 | 7D14 • P6041 • CT-1 |