7A19: Difference between revisions

912 bytes added ,  14 August 2014
specs
(pics)
(specs)
Line 4: Line 4:
image=7a19-front.jpg |  
image=7a19-front.jpg |  
caption=7A19 front view|
caption=7A19 front view|
years=? |
years=1971 — ? |
type=Vertical Amplifier|
type=Vertical Amplifier|
series=[[7000-series scopes]]|
series=[[7000-series scopes]]|
Line 15: Line 15:


An option (#4) was available that added a variable signal delay, intended to match timing between multiple channels.
An option (#4) was available that added a variable signal delay, intended to match timing between multiple channels.
The pre-charge setting on the input coupling switch is intended for situations where there might be residual charge on the input coupling capacitor that could overload the input.  To use it, one sets the switch to PRE-CHG before connecting the inout signal, then waits two seconds before switching to AC (LF point is 1 kHz).  The PRE-CHG setting also serves as a ×100 attenuator having a 5 kΩ input impedance in series with 2 μF, extending LF cutoff down to 20 Hz. In the AC GND position, the input is disconnected from the amplifier and terminated in a capacitively coupled 50 Ω load.


The 7A19 uses the [[155-0068-00]] amplifier IC.
The 7A19 uses the [[155-0068-00]] amplifier IC.


==Specifications==
==Specifications==
* Input impedance: 50 Ω
{{BeginSpecs}}
* Bandwidth: 600 MHz
{{Spec | Input impedance | 50 Ω  }}
{{Spec | Bandwidth | 600 MHz (500 MHz in [[7904]]) }}
{{Spec | Deflection | 10 mV/Div to 1 V/Div, 1—2—5 sequence. Pre-charge circuit may be used as a calibrated ×100 attenuator. }}
{{Spec | Maximum input | 2 W average or 50 Div, in AC mode 100 V DC+peak AC }}
{{Spec | Variable delay (Opt.4) | -0.5 ns to +0.5 ns}}
{{EndSpecs}}


==Pictures==
==Pictures==
Line 50: Line 57:


[[Category:7000 series vertical plugins]]
[[Category:7000 series vertical plugins]]
[[Category:Specifications needed]]