P6013
The Tektronix P6013/P6013A is a ×1000, high-voltage oscilloscope probe.
The P6013 was introduced in 1961, the P6013A in 1966.
Key Specifications
Input impedance | 100 MΩ // 3 pF |
---|---|
Attenuation | 1 : 1000 |
Rise time | 14 ns (specified with 545B and Type K) |
Bandwidth | 25 MHz |
Input voltage | 12 kV maximum, derate above 100 kHz |
Connector | UHF or BNC, no readout pin |
P6013A Compensation Boxes
- 015-0081-00 UHF 10ft cable
- 015-0082-00 UHF 25ft cable
- 015-0083-00 BNC 10ft cable
- 015-0084-00 BNC 25ft cable
Pictures
P6013
-
P6013 in 1963 Catalog
-
Probe core without plastic housing
-
Probe core without plastic housing
-
Compensation box
-
Compensation box internal
-
Probe internal
-
Probe internal. See white spiral insulator that splays flanges for compensation adjustment
P6013A
-
-
-
Compensation box
-
-
-
-
Schematics
-
Derating curve
-