Neon lamps are used for at least three different things in Tek instruments:

  1. Indicator lamps, e.g., for power, beam position, uncalibrated status, or a decimal point
  2. Voltage clamp, similar to how a zener diode is used
  3. In relaxation oscillators, e.g. in 7000-series power supplies
Broken lead (left) on neon in 585 time base

Neon lamps fail more than most other components. A common failure mode is for the leads to break off, often close to the glass bulb, due to corrosion and vibration. Another failure mode is for the I-V characteristic to drift.

Neon lamps are used as a voltage clamp in the CRT circuit for setting the CRT grid voltage in many Tek instruments. A typical example is seen in the 561A:

If the neon lamps fail, the CRT grid voltage will be affected.

Another common use is for DC bias shifting, e.g. in 500-series timebase circuits. In such circuits, a 56 V Zener diode may be a possible replacement for the neon.


When in doubt, replace the neon lamps. In a pinch, it may be possible to reattach broken leads after careful grinding of the glass.

See also

Types and data

Type Tek P/N Voltage Current Notes
Ignition Operating Nominal
NE-2 150-002 76 (60−90) V 58 V 0.3 mA =~ modern type A1A
NE-2V 150-030 76 (60−90) V 58 (46-78) V 0.6 mA short length, formed tip for end-on viewing; dark compensated; =~ modern type A2B
NE-23 150-027 74 (60−90) V 59 V 0.3 mA dark compensated

Please add

Dark compensation

Neon lamps require a higher voltage to ignite if operated in total dark, this is known as Dark effect. This was compensated in some types by a "mild radioactive additive" to help with ionization, typically a small amount of Krypton-85 (beta emitter, 10.8 years half life) added to the gas filling.

After 50 years, radiation from this source will have reduced to ~3% of the intensity at new. Modern NE-2 variants will likely not contain such an additive in the first place.