7D15

From TekWiki
Revision as of 18:03, 15 July 2023 by Qfissler (talk | contribs) (Components sect)
Jump to navigation Jump to search
Tektronix 7D15
225 MHz frequency counter
Tektronix 7D15

Compatible with 7000-series scopes

Produced from 1972 to 1990

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 7D15 is a 225 MHz frequency counter plug-in for 7000-series scopes, introduced in November 1972.

The 7D15 is optimized for timing measurements, having a 100 MHz oscillator and interval measurement averaging capability. It has two inputs and can measure frequency, period or time difference.

The front panel uses SMB connectors for arming, clock in/out and reset signals. The arming input for channel A is active-high whereas that for channel B is active-low. When one or both are connected to the scope's delayed gate output, the delayed timebase can be used to select the part of the signal to be counted, e.g. for burst or A-B interval measurements. With this connection, the arming interval is directly visible as the intensified trace in the "A intensified by B" display mode.

When installed in a horizontal plug-in bay, the 7D15 can use the mainframe's trigger signal as its input. In a vertical bay, it can display the gate signal. In "true gate" mode, this is the actual counter gate, however, this has a low repeat rate due to the counter's dead time. The "pseudo gate" mode improves this by showing the gate whenever the arming and trigger conditions are met, whether the counter is active or not. A third mode shows channel B's gate. The gate display signal is also available on a dedicated BNC output that can be routed to a scope input when the 7D15 is installed in a H slot.

Key Specifications

     — Frequency Mode
Input frequency DC to 225 MHz
Resolution 0.1 Hz min.
     — Period Mode
Range 10 ns to 105 s, Averaging ×1, ×10, ×100 or ×1000
Resolution 10 ps max.
     — Time Interval Mode
Range 6 ns to 105 s, Averaging ×1, ×10, ×100 or ×1000
Resolution 0.1 ns usable
     — Frequency Ratio Mode
Range 10-7 to 104
     — Totalize Mode
Range 0 to 108 counts
     — Manual Stopwatch Mode
Range 0 to 105 seconds
     — Inputs CH A + CH B
Frequency Range DC (AC coupled: 5 Hz) to 225 MHz
Sensitivity 100 mVp-p (from TRIG SOURCE: 0.5 Div)
Max. input 200 V DC linearly derated to 20 V at 200 MHz
Min. pulse width 5 ns
Input impedance 1 MΩ // 22 pF

Internals

The 7D15 uses a number of Tek-made custom chips. The 155-0086-00, 155-0087-00 and 155-0088-00 legend generators are specific to this plug-in. The 155-0090-00 or 155-0171-00 four decade counter/latch/DAC chips implement the lower six counter digits. For the topmost two digits, the 7D15 employs ECL counters. ECL logic requires a −5 V supply, which a switching regulator (board A8) generates from the −15 V rail.

The 5 MHz signal from the (non-ovenized) internal reference crystal oscillator is divided down to a 1 MHz master clock. Optionally, the 1 MHz can be supplied externally as well. An internal VCO, phase-locked to the 1 MHz master, produces a 100 MHz input to the counter chain for timing measurements.

Links

Prices

Year 1973 1976 1980 1984 1990
Price $1,475 $1,600 $2,200 $3,200 $4,400
In 2023 dollars $10,000 $8,500 $8,100 $9,300 $10,200

Pictures

Components

Custom ICs used in the 7D15

Page Model Part nos Description Designers Used in
155-0086-00 M165 155-0086-00 custom legend generator Roger McCoy Mike Metcalf 7D15
155-0087-00 M166 155-0087-00 custom legend generator Roger McCoy Mike Metcalf 7D15
155-0088-00 M167 155-0088-00 custom legend generator Roger McCoy Mike Metcalf 7D15 7L13 7L14
155-0090-00 M059 155-0090-00 155-0090-01 155-0090-02 four-decade counter, latch and D/A converter Mike Metcalf 7B85 7D01 7D12 7D15 7J20
155-0171-00 M150A 155-0171-00 four-decade counter, latch and D/A converter Mike Metcalf 7B85 7D01 7D12 7D15 7J20