[[File:067-0502-00 front.jpg | thumb | 350px |right]]
{{Instrument Sidebar
|manufacturer=Tektronix
|model=067-0502-00
|class=Signal generator
|series=
|summary=Amplitude calibrator
|image=067-0502-00 front.jpg
|caption=Tektronix 067-0502-00
|introduced=(?)
|discontinued=(?)
|designers=
|manuals=
* [[Media:062-0808-00.pdf|Tektronix 067-0502-00 Manual]] (PDF)
* [[Media:Tek 067-0502-00.pdf|Tektronix 067-0502-00 Manual]] (PDF, OCR)
}}
The '''Tektronix 067-0502-00''' is an instrument designed for calibrating oscilloscope calibrators.
The '''Tektronix 067-0502-00''' is an instrument designed for calibrating oscilloscope calibrators.
It is very similar to the [[067-0502-01]].   
It is very similar to the [[067-0502-01]].   


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Output Signal | DC+, DC-, Squarewave}}
{{Spec | Output | DC+, DC-, Squarewave}}
{{Spec | Amplitude Range | 0.2 mV to 100 V in 1−2−5 sequence, 5 mA in current loop}}
{{Spec | Amplitude range | 0.2 mV to 100 V in 1−2−5 sequence, 5 mA in current loop}}
{{Spec | Amplitude Accuracy | Within 0.25% into 1 MΩ load}}
{{Spec | Amplitude accuracy | Within 0.25% into 1 MΩ load}}
{{Spec | Squarewave Repetition Rate | 1 kHz within 20% }}
{{Spec | Squarewave repetition rate | 1 kHz within 20% }}
{{Spec | Maximum Input Voltage | 100 V }}
{{Spec | Maximum input voltage | 100 V }}
{{Spec | 100x Amplifier Gain Accuracy | ±1% }}
{{Spec | 100x Amplifier gain accuracy | ±1% }}
{{Spec | 100x Amplifier Risetime | < 35  μs }}
{{Spec | 100x Amplifier risetime | < 35  μs }}
{{Spec | 100x Amplifier Output Range | ≥ ±20 V, ±5 mA }}
{{Spec | 100x Amplifier output range | ≥ ±20 V, ±5 mA }}
{{Spec | 100x Amplifier Output Resistance | approx. 250 Ω}}
{{Spec | 100x Amplifier Output resistance | approx. 250 Ω}}
{{EndSpecs}}
{{EndSpecs}}
==Manuals==
* [[Media:062-0808-00.pdf|Tektronix 067-0502-00 Manual (PDF)]]
* [[Media:Tek 067-0502-00.pdf|Tektronix 067-0502-00 Manual (PDF, OCR)]]


==Comparison with 067-0502-01==
==Comparison with 067-0502-01==
Line 26: Line 35:
TekWiki asks the question: What is the difference? I have both units and have done an extensive review.
TekWiki asks the question: What is the difference? I have both units and have done an extensive review.


Looking at the front panels [TNX 4 pix] of the –00 & the –01,  
Looking at the front panels [TNX 4 pix] of the –00 & the –01, it seems that the –01 dropped the × 100 Amplifier section.   
it seems that the –01 dropped the × 100 Amplifier section.   
The front panel is re-laid out, but what remains seems to be identical to the corresponding sections from the –00.   
The front panel is re-laid out,  
but what remains seems to be identical to the corresponding sections from the –00.   
In other words, the –00 provides a superset of the functionality of the -01.
In other words, the –00 provides a superset of the functionality of the -01.


Note that the –00 transformer [T310] has 6 windings  
Note that the –00 transformer [T310] has 6 windings and the –01 transformer [also T310] has 5 windings.   
and the –01 transformer [also T310] has 5 windings.   
Some currents are different, as indicated.
Some currents are different, as indicated.


Line 130: Line 136:
==Pictures==
==Pictures==
<gallery>
<gallery>
File:067-0502-00 front.jpg
067-0502-00 front.jpg
Image:067-0502-00.JPG
067-0502-00.JPG
</gallery>
</gallery>


[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:Amplitude Calibrator]]
[[Category:Amplitude Calibrators]]

Navigation menu