067-0657-00: Difference between revisions

no edit summary
No edit summary
No edit summary
Line 17: Line 17:


The calibration fixture is triggered from an external signal (such as a trigger output from a time-mark generator) applied to the front-panel TRIG IN connector.
The calibration fixture is triggered from an external signal (such as a trigger output from a time-mark generator) applied to the front-panel TRIG IN connector.
==Internals==
The 067-0657-00 was the result of some fundamental research by [[Bruce Hofer]] inspired by production issues in the calibration of early [[7904]] scopes. This lead to a new sweep circuit that uses current steering in a differential pair to start the charging of the timing capacitor as is discussed in [[Patent_US_4009399A|patent 4009399]]. The sweep circuit in the 067-0657-00 follows the patent application but does not implement the baseline stability circuit, which was incorporated in the [[7B92A]].


==Links==
==Links==
* [[Bruce Hofer]], ''[https://vintagetek.org/years-at-tektronix-hofer/ My Years at Tektronix]
* [[Bruce Hofer]], ''[https://vintagetek.org/years-at-tektronix-hofer/ My Years at Tektronix]
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/067-0657-00%20067-0657-99/067-0657-99_067-0657-00.html 067-0657-xx @ amplifier.cd]
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/067-0657-00%20067-0657-99/067-0657-99_067-0657-00.html 067-0657-xx @ amplifier.cd]
* [[Patent_US_4009399A| US Patent 4009399 Gated Ramp Generator]]


==Pictures==
==Pictures==
1,875