Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally. | Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally. | ||
Signal processing includes Fourier Transform (FFT) and Spectral Lines. | Signal processing includes Fourier Transform ([[wikipedia:Fast_Fourier_transform|FFT]]) and Spectral Lines. | ||
The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary. | The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary. With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected. | ||
With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected. | |||
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops. | The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops. | ||
Line 29: | Line 28: | ||
It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest. | It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Frequency Ranges | DC to 100 kHz }} | {{Spec | Frequency Ranges | DC to 100 kHz }} | ||
Line 51: | Line 39: | ||
{{Spec | Input Impedance | 1 MΩ; 200 pF }} | {{Spec | Input Impedance | 1 MΩ; 200 pF }} | ||
{{Spec | Max Input Level | ±30 V }} | {{Spec | Max Input Level | ±30 V }} | ||
{{Spec | Weight | Standard accessories: 11.8 kg (26 lbs) }} | {{Spec | Weight | Standard accessories: 11.8 kg (26 lbs) }} | ||
{{Spec | Power | 90 − 250 V<sub>AC</sub>, 48 to 66 Hz, >120 W }} | {{Spec | Power | 90 − 250 V<sub>AC</sub>, 48 to 66 Hz, >120 W }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Front panel: | |||
* CH1, CH2, CH3, and CH4 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); | |||
* OUTPUT [[BNC connector]] (50 Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.) | |||
Rear panel: | |||
* SYSTEM INTERCONNECT [[DB9 connector|DB-9 male]] used for both External triggering, and External sampling inputs. | |||
All pins TTL-level: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; | |||
pin 9 is the external sampling input); | |||
* SERIAL PORT [[BNC connector]] (linking to the host computer via a Tektronix supplied serial interface cable). | |||
==Options== | ==Options== |