{{Plugin Sidebar |
{{Plugin Sidebar  
manufacturer=Tektronix |series=560-series scopes |type= 3T6 |
|manufacturer=Tektronix  
summary=Programmable Sampling Sweep |
|series=560-series scopes  
image=3T6_front.JPG |
|type=3T6  
caption=3T6 sweep unit |
|summary=Programmable Sampling Sweep  
designers=  |
|image=3T6_front.JPG  
introduced=1969 |
|caption=3T6 sweep unit  
discontinued=198(?) |
|designers=   
manuals=
|introduced=1969  
|discontinued=(?)
|manuals=
* [[Media:070-0761-00.pdf|Tektronix 3T6 manual]] (PDF)
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu)
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu)
}}
}}
Line 14: Line 17:


In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23.
In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23.
J24 is used for programming the 3T6.
J24 is used for programming the 3T6.   P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal.   
P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal.   
Both of these connectors mate with corresponding connectors in the 568.
Both of these connectors mate with corresponding connectors in the 568.


Line 22: Line 24:
The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.
The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.


Mod 651C give  100 / 1000 samples/sweep switch.  Orginal has 1 / 1000 samples/sweep switch.
Mod 651C give  100 / 1000 samples/sweep switch.  The original has 1 / 1000 samples/sweep switch. Later units appear to have the 100 / 1000 switch as standard.  


==Specifications==
The indicator lamps in the 'Time/Div' display can occasionally burn out. They can be replaced with 5V, 80mA, 2.5mm x 4.5mm, 'grain of wheat' style lamps. 
[[Category:Specifications needed]]
 
''please add''
{{MissingSpecs}}


==Pictures==
==Pictures==
Line 37: Line 39:
3t6_rear.JPG|rear view
3t6_rear.JPG|rear view
</gallery>
</gallery>
{{Parts|3T6}}


[[Category:560 series plugins]]