a 74S00 TTL quad NAND gate configured as a flip-flop.
a 74S00 TTL quad NAND gate configured as a flip-flop.


The power supply is linear and regulated using opamps as error amplifiers.
The power supply is linear and regulated using op amps as error amplifiers.


The vertical and horizontal amplifiers are made of discrete bipolar transistors
The vertical and horizontal amplifiers are made of discrete bipolar transistors

Revision as of 14:16, 24 December 2014

{{{manufacturer}}} 
35 MHz dual-trace scope
Tek 442

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 442 is a 35 MHz dual-trace oscilloscope with a single timebase.

Specifications

please add

The anode voltage on the CRT is 10kV and the standard phosphor was P31.

A Tektronix 442 consumes 36 watts and weighs about 20 pounds.

Internals

Serials numbers from B010100 to B010786 use the 154-0729-00 CRT. Starting with serial number B010787, the 154-0804-00 CRT is used.

Triggering is done using a trigger amplifier made of discrete bipolar transistors and a 74S00 TTL quad NAND gate configured as a flip-flop.

The power supply is linear and regulated using op amps as error amplifiers.

The vertical and horizontal amplifiers are made of discrete bipolar transistors except for the dual-JFETs that are used as high-impedance buffers at the signal inputs.