568: Difference between revisions

1,655 bytes added ,  22 December 2023
no edit summary
(template change)
No edit summary
 
(24 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 568 |
|manufacturer=Tektronix
summary=Sampling scope |
|series=560-series scopes
image=568 708p front.jpg |
|model=568
caption=Tektronix 568 Mod 708p front |
|summary=Sampling scope
introduced=1967 |
|image=568_1.JPG
discontinued=(?) |
|caption=Tektronix 568 front, with [[3S6]] and [[3T6]] plugins
 
|introduced=1967  
manuals=
|discontinued=1987
* [http://bama.edebris.com/download/tek/568/568.djvu Tektronix 568 Manual (DjVu)]
|designers=
* [http://w140.com/tek-568.pdf Tektronix 568 Manual (PDF)]
|manuals=
* [http://w140.com/tek_readout_oscilloscopes_1968_catalog.pdf "Digital Readout Introduction" in 1968 Catalog (PDF)]
* [[Media:070-0596-00.pdf|Tektronix 568 Manual]]<small><br />Alternate: [http://bama.edebris.com/download/tek/568/568.djvu DjVu @ BAMA]</small>
* [[Media:Tek readout oscilloscopes 1968 catalog.pdf|"Digital Readout Introduction" in 1968 Catalog]]
* [[Media:Tek 568 fcp jan 1967.pdf]]
}}
}}
The 568 is a [[sampling oscilloscope]] that was [[introduced in 1967]] that takes 3S- and 3T-series plug-ins.   
The '''Tektronix 568''' is a [[sampling oscilloscope]], [[introduced in 1967]], which takes 3S- and 3T-series plug-ins.   
Although it was intended to be used for sampling, it can also be used with non-sampling plug-ins of the 3A and 3B series.
Although it was intended to be used for sampling,
it can also be used with non-sampling plug-ins of the 3A and 3B series.


Like the [[561]] and [[564]], the 568 does not contain vertical or horizontal amplifiers. The plug-ins directly drive the deflection plates. The 568 has multipin connectors on its rear panel that are routed to multipin connectors on the plug-ins. This is to support external control and measurement using, for example, a [[230]] and [[241]].
Like the [[561]] and [[564]], the 568 does not contain vertical or horizontal amplifiers.
The plug-ins directly drive the deflection plates.
The 568 has multi-pin connectors on its rear panel that are routed to multi-pin connectors on the plug-ins.
This is to support external control and measurement using, for example, a [[230]] and [[241]].
The typical cable for connecting the [[568]] to the [[230]] is the [[012-0119-01]].


Two sampling heads can be interfaced directly to the 568 using the [[012-0130-00]] cable, or
Two sampling heads can be interfaced directly to the 568 using the [[012-0130-00]] cable, or
multiple sampling heads can be interfaced using an multiplexer such as the [[286]], [[287]],
multiple sampling heads can be interfaced using an multiplexer such as the [[286]], [[287]],
or [[R288]].
or [[R288]].
CRT was the [[T5032]]-2-1 ([[154-0454-00]]) or [[T5611]]-2-1 ([[154-0613-01]]).


The 568 was distributed as a self-contained instrument and also  
The 568 was distributed as a self-contained instrument and also  
as a component of integrated test and measurement systems
as a component of integrated test and measurement systems
such as the [[S-3100]].
such as the [[S-3100]].
As a part of the test and measurement systems,
the 568 was sold at least until 1986.
A modification, 708P, was available for the 568 to give it a head multiplexer instead of a CRT. Head multiplexer is similar with [[286]]


A modification, 708P, was available for the 568 to give it a head multiplexer instead of a CRT.
{{BeginSpecs}}
{{Spec | Bandwidth            | sampling, DC to  14,5 GHz (with [[3S2]] and [[S-4]] head, may vary with other plug-ins);<br />realtime, DC to 15 MHz (with [[3A5]], may vary with other plug-ins)  }}
{{Spec | Rise time            | sampling, 25 ps;<br />realtime, 24 ns }}
{{Spec | Acceleration voltage | 3.5 kV}}
{{Spec | Screen Area          | 8 cm × 10 cm  }}
{{Spec | Calibrator          | 0.5 V , 5 V (p-p) into 1 MΩ, 50mV, 0.5 V (p-p) into 50 Ω, selectable 1 kHz( -50 % / +100%)and 100 kHz (0.05 %), ( Serial B150629 below  20 kHz instead 100 kHz)}}
{{Spec | Screen Area          | 8 cm × 10 cm  }}
{{Spec | Power                | 100/115/124/200/230/248 V<sub>AC</sub> ±10%, selected via primary voltage selector and voltage range selector switches, 48 Hz to 66 Hz; max 210 W with plug-ins }}
{{Spec | Thermal Protection  | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Construction        | Aluminum alloy chassis. Anodized front panel}}
{{EndSpecs}}


==Specifications==
==Links==
[[Category:Specifications needed]]
* [http://www.museum-nt.de/objekte/tek_568.html Tek 568 @ museum-nt.de]
{{Documents|Link=568}}


==Pictures==
==Pictures==


<gallery>
<gallery>
Image:568 708p front.jpg|568 Mod 708P front
568_1.JPG            |568  front
Image:568 708p switching.jpg|568 Mod 708P head multiplexer circuitry
230_568_0.JPG        |230 and 568 measuring risetime
Image:568 708p rear.jpg|568 Mod 708P front
568_rear.JPG          |568 rear 
568_i_top.JPG        |568 top inside
568_i_bot.JPG        |568 bottom inside
568 708p front.jpg   |568 Mod 708P front
568 708p switching.jpg|568 Mod 708P head multiplexer circuitry
568 708p rear.jpg     |568 Mod 708P rear
</gallery>
</gallery>


Line 41: Line 70:
[[Category:560 series scopes]]
[[Category:560 series scopes]]
[[Category:Sampling scopes]]
[[Category:Sampling scopes]]
[[Category:Image needed]]