570: Difference between revisions

Jump to navigation Jump to search
No edit summary
No edit summary
Line 10: Line 10:
|designers=John Kobbe
|designers=John Kobbe
|manuals=
|manuals=
* [[Media:070-167.pdf|Tektronix 570 Manual 070-167]] (PDF, OCR, good quality)
* [[Media:070-167.pdf|Tektronix 570 Manual 070-167]] (OCR, good quality)
* [[Media:070-359.pdf|Tektronix 570 Manual 070-359 (1963)]] (PDF, good quality)
* [[Media:070-359.pdf|Tektronix 570 Manual 070-359 (1963)]] (good quality)
* [https://w140.com/mmm/tek-570.pdf Tektronix 570 Manual (mediocre quality, PDF)]
<!-- * [https://w140.com/mmm/tek-570.pdf Tektronix 570 Manual] (mediocre quality) -->
* [https://w140.com/tek_fcp/tek_570_fac_cal.pdf Tektronix 570 Factory Calibration Procedure 1959 (PDF)]
<!-- * [https://w140.com/tek_fcp/tek_570_fac_cal.pdf 570 Factory Calibration Procedure 1959] -->
* [[Media:Tek 570 fcp feb 1964.pdf|Tektronix 570 Factory Calibration Procedure 1964 (PDF)]]
<small>
* [[Media:Tek 570 fcp.pdf]]
'''Calibration'''
* [[Media:Tek 570 10 amp request.pdf|Request from GE for a 10-amp 570]]
* [[Media:Tek 570 fcp feb 1964.pdf|570 Factory Calibration Procedure 1964]]
* [[Media:Tek 570 fcp.pdf|570 Factory Calibration Procedure 1959]]
</small>
}}
}}
The '''Tektronix 570''' was Tek's first curve tracer.  It is a curve tracer for tubes, introduced in 1955.
The '''Tektronix 570''' was Tek's first curve tracer, [[introduced in 1955]].  It is a curve tracer for vacuum tubes.
It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.
It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.  


A selectable screen voltage is available for testing tubes with screens.   
A selectable screen voltage is available for testing tubes with screens.   
The plate voltage is measured and applied to the X-axis of the display.   
The plate voltage is measured and applied to the X-axis of the display.   
Plate current is measured and amplified and is applied to the Y-axis of the display.   
Plate current is measured and amplified and is applied to the Y-axis of the display.   
[[John Kobbe]] had a key role in the development of both the 570 and [[575]] curve tracers.


{{MissingSpecs}}
{{MissingSpecs}}
Line 43: Line 47:


A [[T0520|T52P1]] CRT is standard in the 570.
A [[T0520|T52P1]] CRT is standard in the 570.
==Links==
* https://vintagetek.org/curve-tracers/
* [[Media:Tek 570 10 amp request.pdf|Request from GE for a 10-amp 570]] (1961)


==Pictures==
==Pictures==