The Tektronix Type 5T3 is a timing plug-in for the Type [[661]] [[sampling oscilloscope]].   
{{Plugin Sidebar
It uses TD253B [[tunnel diodes]] for triggering.   
|manufacturer=Tektronix
It has a high-impedance external trigger input that is buffered by an [[8056]] [[nuvistor|Nuvistor]] cathode follower.
|series=661
The 5T3 also has a 50-ohm external trigger input with no buffering stage. 
|type=5T3
This low-impedance trigger input is capable of operation up to 5GHz.
|summary=Timing plugin
|image=Tek 5t3 front.jpeg
|caption=Tek 5T3
|introduced=1965
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-0470-00.pdf|Tektronix 5T3 Manual]]
* [[Media:Tek 5t3 field training.pdf|Tektronix 5T3 Field Training Kit]] (low quality, no OCR)
* [[Media:Tek 5t3 training ocr4.pdf|Tektronix 5T3 Field Training Kit]] (high quality, OCR)
* [[Media:Tek 5t3 cal outline.pdf|Tektronix 5T3 Calibration Outline]] (OCR)
}}
The '''Tektronix Type 5T3''' is a timing plug-in for the Type [[661]] [[sampling oscilloscope]].   
It uses [[TD253|TD253B]] [[tunnel diodes]] for triggering.   


* [http://w140.com/kurt/tektronix_5t3.pdf Tektronix 5T3 Manual (PDF)]
The 5T3 can be triggered from any of four different sources:
* [http://w140.com/tek_5t3_field_training.pdf Tektronix 5T3 Field Training Kit (PDF)]
# Internal trigger from the sampling plug-in, via interconnect J9.
# Internal trigger from the calibrator module in the 661 mainframe. This works up to 1 GHz.
# External trigger to the high-impedance BNC trigger input. This input is buffered by an [[8056]] [[nuvistor|Nuvistor]] cathode follower. This can be used for triggering on signals up to 20 MHz.
# External trigger to the 50 Ω [[GR-874]] trigger input. This input can drive either of two selectable signal paths:
#* A path where the trigger signal skips the high-impedance Nuvistor input buffer but is still buffered by Q64 and Q124 (1 GHz NPN transistors, part number [[151-0138-00]]) before the tunnel diode trigger event recognizer circuit. This path provides triggering up to 500 MHz.
#* A passive low-impedance path, capacitively coupled to a tunnel diode for "UHF SYNC" mode. This works up to 5 GHz.


The 5T3 can also be set to free-run mode.


{{MissingSpecs}}
==Links==
{{Documents|Link=3S3}}
==Pictures==
<gallery>
<gallery>
Image:5t3_front.jpg|front view
5t3_front.jpg|front view
Image:5t3_left.jpg|left view
5t3_left.jpg|left view
Image:5t3_right.jpg|right view
5t3_right.jpg|right view
Image:5t3_top.jpg|top view
5t3_top.jpg|top view
Image:5t3_bottom.jpg|bottom view
5t3_bottom.jpg|bottom view
</gallery>
</gallery>
==Components==
{{Parts|5T3}}
[[Category:661 plugins]]
[[Category:Sampling plugins]]