BNC connector with readout ring: Difference between revisions

no edit summary
(fixed now broken link to sci.electronics forum through wayback machine link)
No edit summary
 
Line 9: Line 9:


* In most [[7000-series plug-ins]], the ring interfaces with the [[7000 series readout system|readout system]]. The [[Media:Tek-plugin-readout.jpg|plug-in circuit]] uses the shift instructions in time slot 1 to implement the change of range. <br />If the probe includes an Identify switch at the tip, this connects the readout pin directly to ground, encoding the special IDENTIFY instruction in time slot 1.
* In most [[7000-series plug-ins]], the ring interfaces with the [[7000 series readout system|readout system]]. The [[Media:Tek-plugin-readout.jpg|plug-in circuit]] uses the shift instructions in time slot 1 to implement the change of range. <br />If the probe includes an Identify switch at the tip, this connects the readout pin directly to ground, encoding the special IDENTIFY instruction in time slot 1.
* [[7000-series scopes]] only display ×1, ×10 and ×100 factors.  [[11000-series_scopes|11K]], [[TDS series scopes|TDS]], [[:Category:2400 series scopes|2400]] and later recognize [[P6015A|×1000]], ×2, ×5, ×200 and possibly other factors.
* Readout-less [[5000-series plug-ins]] and a number of standalone scopes of the same era, e.g. many of the [[400-series scopes]] such as [[464]], use the ring to detect a ×10 (but not a ×100) probe, and indicate the correct scale factor using front-panel lamps or LEDs. The [[485]] also uses the probe ring and utilizes a TEK custom IC [[155-0076-00]] and three LEDs to indicate ×1, ×10, and ×100 probes.
* Readout-less [[5000-series plug-ins]] and a number of standalone scopes of the same era, e.g. many of the [[400-series scopes]] such as [[464]], use the ring to detect a ×10 (but not a ×100) probe, and indicate the correct scale factor using front-panel lamps or LEDs. The [[485]] also uses the probe ring and utilizes a TEK custom IC [[155-0076-00]] and three LEDs to indicate ×1, ×10, and ×100 probes.
* [[7000-series scopes]] only display ×1, ×10 and ×100 factors.  [[11000-series_scopes|11K]], [[TDS series scopes|TDS]], [[:Category:2400 series scopes|2400]] and later recognize [[P6015A|×1000]], ×2, ×5, ×200 and possibly other factors.
* The [[7A14]] plugin uses the same BNC connector with a ring but the ring serves a different purpose, which is to detect the difference between the [[P6021]] and [[P6022]] probes, and switching in appropriate gain and frequency compensation.  The P6021 (or a [[131-0750-00]] adapter for the [[P6019]]) shorts this ring to ground, directly switching three relays connected to −15 V internally.
* The [[7A14]] plugin uses the same BNC connector with a ring but the ring serves a different purpose, which is to detect the difference between the [[P6021]] and [[P6022]] probes, and switching in appropriate gain and frequency compensation.  The P6021 (or a [[131-0750-00]] adapter for the [[P6019]]) shorts this ring to ground, directly switching three relays connected to −15 V internally.