36,479
edits
No edit summary |
|||
(2 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix P6009''' is a 120 MHz, | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6009 | |||
|summary=120 MHz, 100×, Passive Probe | |||
|image=Tek p6009 0.jpg | |||
|caption=P6009 with readout BNC connector | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0401-01.pdf|Tektronix P6009 Manual]] | |||
* [[Media:Tek p6009 20pf fcp may 1967.pdf|Tektronix P6009 Factory Calibration Procedure]] | |||
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description] | |||
}} | |||
The '''Tektronix P6009''' is a 120 MHz, 100x, passive probe for scopes with 1 MΩ input impedance. | |||
There are different connector options: | There are two different connector options: | ||
* Part number 010-0170-00 is a P6009 with a 9 foot cable and a plain BNC connector. | * Part number 010-0170-00 is a P6009 with a 9 foot cable and a plain BNC connector. | ||
* Part number 010-0264-01 is a P6009 with a 9 foot cable and a [[BNC connector with readout ring]]. The extra pin on BNC connector allows the probe's 100x attenuation to be detected. However the P6009 does not have an "Identify" switch. | * Part number 010-0264-01 is a P6009 with a 9 foot cable and a [[BNC connector with readout ring]]. The extra pin on BNC connector allows the probe's 100x attenuation to be detected. However the P6009 does not have an "Identify" switch. | ||
{{BeginSpecs}} | |||
{{Spec | Attenuation | 100× ±3% with 1 MΩ ±2% scope input }} | |||
{{Spec | Maximum Voltage | 1.5 kV DC + AC peak, derated above 200 kHz }} | |||
{{Spec | Compensation range | 15 - 47 pF }} | |||
{{Spec | Bandwidth | 120 MHz }} | |||
{{Spec | Input capacitance | 2.5 pF }} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== | ||
Line 25: | Line 43: | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:High voltage oscilloscope probes]] | [[Category:High voltage oscilloscope probes]] | ||