[[File:Tek P6015 box.jpg|thumb|300px|right|Tektronix P6015 in box]]
{{Probe Sidebar
The '''Tektronix P6015''' is a 1000X high-voltage probe usable up to 20 kV (40 kV peak pulse).  It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
|manufacturer=Tektronix
|model=P6015
|summary=20(40) kV, ×1000 Passive Probe
|image=Tek_P6015_1.jpg
|caption=P6015
|for=1 MΩ scope inputs
|introduced=(?)
|discontinued=(?)
|manuals=
* [https://w140.com/p6015.pdf Tektronix P6015 Manual] (Copyright date 1963)
* [https://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual] (Revision date 1985)
* [https://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual]
* [https://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic]
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description]
}}
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
 
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak).  
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.


The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
[[File:Tek P6015 derating.jpg|300px|thumb|right|Derating curves]]


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Attenuation ratio | 1000X }}
{{Spec | Attenuation ratio | 1000× }}
{{Spec | Input impedance | 100 MΩ // 3 pF }}
{{Spec | Input impedance   | 100 MΩ // 3 pF }}
{{Spec | Rise time | 4.67 nsec (10' cable), 14 nsec (25' cable) }}
{{Spec | Rise time         | 4.67 ns (10' cable), 14 ns (25' cable) }}
{{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }}
{{Spec | Bandwidth         | 75 MHz (10' cable), 25 MHz (25' cable) }}
{{Spec | Compensation Range | 15-50 pF }}
{{Spec | Compensation Range | 15-50 pF }}
{{Spec | Max. input voltage |  
{{Spec | Max. input voltage |  
Line 17: Line 33:
}}
}}
{{EndSpecs}}
{{EndSpecs}}
[[File:Tek P6015 term box.jpg|300px|thumb|right|Termination box]]
==Manuals==
* [http://w140.com/p6015.pdf Tektronix P6015 Manual (Copyright date 1963, PDF)]
* [http://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual (Revision date 1985, PDF)]
* [http://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual (PDF)]
* [http://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic (PDF)]
* [http://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description (PDF)]


==Links==
==Links==
Line 34: Line 41:
==Pictures==
==Pictures==
<gallery>
<gallery>
P6015 BW.png
Tek P6015 box.jpg | Tektronix P6015 in box
Tek p6015 schem.png
Tek hv dielectric fluid.jpg|Can of Freon Dielectric Fluid
Tek_P6015_1.jpg
Tek_P6015_1.jpg
Tek_P6015_2.jpg
Tek_P6015_2.jpg
Tek_P6015_3.jpg
Tek_P6015_3.jpg
Tek_P6015_4.jpg
Tek_P6015_4.jpg
P6015 BW.png
Tek p6015 schem.png
Tek P6015 derating.jpg      | Derating curves
Tek hv dielectric fluid.jpg | Can of Freon Dielectric Fluid
Tek P6015 term box.jpg      | Termination box
</gallery>
</gallery>


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]