{{Probe Sidebar | |||
The '''Tektronix P6015''' is a | |manufacturer=Tektronix | ||
|model=P6015 | |||
|summary=20(40) kV, ×1000 Passive Probe | |||
|image=Tek_P6015_1.jpg | |||
|caption=P6015 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [https://w140.com/p6015.pdf Tektronix P6015 Manual] (Copyright date 1963) | |||
* [https://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual] (Revision date 1985) | |||
* [https://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual] | |||
* [https://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic] | |||
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description] | |||
}} | |||
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | |||
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). | |||
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used. | |||
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation ratio | | {{Spec | Attenuation ratio | 1000× }} | ||
{{Spec | Input impedance | 100 MΩ // 3 pF }} | {{Spec | Input impedance | 100 MΩ // 3 pF }} | ||
{{Spec | Rise time | 4. | {{Spec | Rise time | 4.67 ns (10' cable), 14 ns (25' cable) }} | ||
{{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }} | {{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }} | ||
{{Spec | Compensation Range | 15-50 pF }} | {{Spec | Compensation Range | 15-50 pF }} | ||
{{Spec | Max. input voltage | | {{Spec | Max. input voltage | | ||
Line 17: | Line 33: | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
Line 34: | Line 41: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
P6015 | Tek P6015 box.jpg | Tektronix P6015 in box | ||
Tek_P6015_1.jpg | Tek_P6015_1.jpg | ||
Tek_P6015_2.jpg | Tek_P6015_2.jpg | ||
Tek_P6015_3.jpg | Tek_P6015_3.jpg | ||
Tek_P6015_4.jpg | Tek_P6015_4.jpg | ||
P6015 BW.png | |||
Tek p6015 schem.png | |||
Tek P6015 derating.jpg | Derating curves | |||
Tek hv dielectric fluid.jpg | Can of Freon Dielectric Fluid | |||
Tek P6015 term box.jpg | Termination box | |||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||