|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
* [[Media:070-0948-03.pdf|Tektronix P6022 | * [[Media:070-0948-03.pdf|Tektronix P6022 Manual -03]] (with termination schematics) | ||
* [[Media:070-0948-04.pdf|Tektronix P6022 Manual]] ( | * [[Media:070-0948-04.pdf|Tektronix P6022 Manual -04]] (newer version without schematics) | ||
}} | }} | ||
The '''Tektronix P6022''' (010-0238-00) is a 50-turn AC current probe for oscilloscopes. It can be used with the included passive termination box (011-0106-00), a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. | The '''Tektronix P6022''' (010-0238-00) is a 50-turn AC current probe for oscilloscopes. It can be used with the included passive termination box (011-0106-00), a [[134|type 134 current probe amplifier]], or a [[3A9]] or [[7A14]] current probe amplifier scope plug-in. | ||
Line 32: | Line 32: | ||
| 1 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div) || 1 mA/Div to 1 A/Div | | 1 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div<br/>(scope @ 50 mV/Div) || 1 mA/Div to 1 A/Div | ||
|- | |- | ||
! Bandwidth ( | ! Bandwidth (–3 dB) | ||
| 60 MHz @ 10 mA/mV || > 40 MHz || 50 MHz | | 60 MHz @ 10 mA/mV || > 40 MHz || 50 MHz | ||
| 200 MHz @ 10 mA/mV || > 70 MHz || 105 MHz | | 200 MHz @ 10 mA/mV || > 70 MHz || 105 MHz | ||
|- | |- | ||
! LF limit ( | ! LF limit (–3 dB) | ||
| 450 Hz @ 2 mA/mV<br/>120 Hz @ 10 mA/mV || < 12 Hz || 25 Hz | | 450 Hz @ 2 mA/mV<br/>120 Hz @ 10 mA/mV || < 12 Hz || 25 Hz | ||
| 8500 Hz @ 1 mA/mV<br/>935 Hz @ 10 mA/mV || < 100 Hz || 250 Hz | | 8500 Hz @ 1 mA/mV<br/>935 Hz @ 10 mA/mV || < 100 Hz || 250 Hz |