Pacific Measurements 1038

Revision as of 01:03, 4 May 2019 by Peter (talk | contribs)

The Pacific Measurements 1038 is a 1 or 2 channel scalar network analyzer incorporating a Tektronix 5000-series scopes display unit, either a D10 long-persistance (P-7 phosphor), D11 split-screen storage or a D14(?) digital storage model, with optional rack mount and GPIB interface.

Options:

  • Horizontal plug-ins H10 (sweep drive), H11 (sweep Drive and memory address circuits), H12 (sweep drive and ratio channel), H13 (sweep drive, memory address circuits and ratio channel) and K11 (replaces H11 and provides amplitude sweep).
  • Vertical plug-ins V10 (log amp and signal conditioning), V11 (log amp, signal conditioning and 256 point memory), V12 (log amp, signal conditioning and 1024 point memory), V13 (log amp, signal conditioning, recording of two calibration curves and 1024 point memory) and V20 (linear amp, 1024 point memory and for use in conjunction with Model 1018B power meter).
  • N10 plug-in (dual channel network analyzer).
  • NS20 plug-in (dual channel network analyzer) with optional NS201 (2 to 18.5 GHz RF source).
  • C10 plug-in calibration fixture and extender kit for direct calibration and check-out of the D14/D14A Mainframe. It has extension cables to permit calibration and maintenance of the H/V system plug-ins.
  • Power input calibrator unit (detector simulator - P/N 15484) will act as a "standard" detector to furnish accurate voltages to the H/V system when it is desired to calibrate the amplitude correction circuitry.

Pacific Measurements later became part of Wavetek.

Key Specifications

     — H/V System
Offset Range ±99.9 dB, 3 digits resolution, accuracy ±0.02 dB/10 dB ±0.05 dB
Drift @ 0 dBm, <0.01 dB/°C (+15° to +45°C );
@ −40 dBm, <0.5 dB/24 Hrs at constant temperature )
Frequency Range 100 kHz to 18.5 GHz ;
with single diode (P/N 12685, 12882, 12883, 13161) detector, 100 kHz to 1 GHz or (P/N 13160) 2 GHz ;
with single diode (P/N 15272) or balanced (P/N 15285) detector, 1 MHz to 26.5 GHz ;
Wavetek Pacific Measurements waveguide detector (P/N 15882), 26.5 GHz to 40.0 GHz ;
other waveguide manufacturers, up to 110 GHz
Power −50 dBm to +10 dBm
Dynamic Range 60 dB (Reference Channel: 40 dB)
Reading Insertion Loss/Gain and Return Loss, 0.02 dB resolution
Noise Floor −70 dB
Power Approx. 100 VA @ 50 − 440 Hz; 100, 120, 240 VAC ±10%
Dimensions benchtop (H x W x D) 381 x 216 x 483 mm (15 x 8.5 x 19 in.);
rackmount (H x W x D) 178 x 483 x 483 mm (7 x 19 x 19 in.)
Weight 18.2 kg (40 lbs) - vertical plug-in 2.3 kg (5 lbs), horizontal plug-in 2 kg (4.4 lbs)
     — Power Detectors (P/Ns 15272, 13782 and 13783 unless noted)
Input Impedance 50 Ω nominal;
75 Ω (P/N 12685, 12882, 13161)
Input Power max. +23 dBm (200 mV) peak or average
Return Loss >20.8 dB, SWR <1.20 from 100 kHz to 1 GHz (P/N 12685, 12882, 12883, 13160, 13161);
>25.0 dB, SWR <1.12 from 1 MHz to 1 GHz;
>18.0 dB, SWR <1.29 from 2 GHz to 12.4 GHz;
>14.0 dB, SWR <1.50 up to 26.5 GHz
Accuracy 3% to 18.5 GHz and 5% to 26.5 GHz
Flatness ±0.5 dB to 18.5 GHz (P/N 15272);
±1.0 dB 18.5 GHz to 26.5 GHz (P/N 15272) ;
±1.0 dB to 18.5 GHz (P/N 13782) ;
±1.0 dB to 18.5 GHz (P/N 13783;
±2.0 dB with type N or APC7 connectors to 18 GHz, ±2.0 dB to 26.5 GHz with APC3.5 connectors
     — Power Detector P/N 15882
Input Power max. +20 dBm (100 mV) peak or average
Return Loss >10 dB, SWR <1.92 from 26.5 to 40 GHz
Accuracy 5% from 26.5 to 40 GHz
Flatness ±2.0 dB from 26.5 to 40 GHz
Temperature 0° to 50°C operating, −50° to +65°C non-operating
Accuracy 0.2 dB to 2 dB from 30 MHz to 26.5 GHz, 0.5 dB to 2 dB from 26.5 GHz to 40 GHz
Cable Length 1.5 m (5 ft)
Weight Approx. 230 g (8 oz)

Prices

Please add

Links

Pictures

1038-D10 with H13 & (bench model) V11, (rack model) x2 V12 Plug-Ins

1038-D11 with H13 & x2 V12 Plug-Ins

1038-D14 with H13 & x2 V12 Plug-Ins

1038-D14A with N10 Plug-In

1038-D14 with NS20 Plug-In

1038-NS201