Probe power: Difference between revisions

Jump to navigation Jump to search
No edit summary
No edit summary
Line 7: Line 7:
* The [[4S1]] provides +100 V, −12.6 V, and −25.2 V.
* The [[4S1]] provides +100 V, −12.6 V, and −25.2 V.
* The [[N]] provides +100 V and 6.3V AC for Type [[P6025]] cathode-follower probes.
* The [[N]] provides +100 V and 6.3V AC for Type [[P6025]] cathode-follower probes.
* The [[454]] and [[015-0073-00]] have a 3-pin probe power connector (Sealectro 55-850-0018-98(?)), the [[454A]] a pair of these, providing +12.5 V and −12.5 V for probes [[P6045]], [[282]], ...
* The [[015-0073-00]] has a 3-pin probe power connector (Sealectro 55-850-0018-98(?)), the [[454]]/[[454A]] a pair of these, providing +12.5 V and −12.5 V for probes [[P6045]], [[282]], ...
* [[7000-series scopes]] (not all models), [[475]], [[485]], the [[1101]] probe power supply, and the [[2707]] tracking generator provide +15 V, +5 V, and −15 V through a [[LEMO S-series connector]].
* [[7000-series scopes]] (not all models), [[475]], [[485]], the [[1101]] probe power supply, and the [[2707]] tracking generator provide +15 V, +5 V, and −15 V through a [[LEMO S-series connector]].
* [[Tekprobe BNC connector|TekProbe BNC]], [[Tekprobe SMA connector|TekProbe SMA]] and [[TekConnect interface|TekConnect]] are proprietary probe-scope interfaces that combine signal and probe power as well as control (e.g. offset voltage), and provide the scope with information about the type of probe connected.   
* [[Tekprobe BNC connector|TekProbe BNC]], [[Tekprobe SMA connector|TekProbe SMA]] and [[TekConnect interface|TekConnect]] are proprietary probe-scope interfaces that combine signal and probe power as well as control (e.g. offset voltage), and provide the scope with information about the type of probe connected.