S-50: Difference between revisions

289 bytes added ,  18 May 2014
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
The Tektronix S-50 is a pulse generator head the produces 400mV pulses
{{Plugin Sidebar |
with a risetime under 25ps.  The pulse output is an  
title=Tektronix S-50 |
[[Connectors#SMA|SMA connector]].  The
summary=Pulse Generator |
PRETRIG OUT and TRIG OUT signals use [[Connectors #BSM|BSM connectors]].
image=Tek s-50.JPG |
caption=S50 Head |
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
years=? – ? |
manuals=
* [http://w140.com/tek_s-50.pdf Tektronix S-50 Manual (46MB, PDF)]
* [http://w140.com/tek_s-series_sampling_heads.pdf Tektronix S-Series Sampling Heads (195MB, PDF)]
}}
 
The Tektronix S-50 is a pulse generator head that produces 400 mV pulses with a rise time under 25 ps.  The pulse output is an  
[[Connectors#SMA|SMA connector]].  The PRETRIG OUT and TRIG OUT signals use [[Connectors #BSM|BSM connectors]].


The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]].
The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]].
The internal timing circuitry of the S-50 uses two [[152-0379-00]] tunnel diodes.
The internal timing circuitry of the S-50 uses two [[152-0379-00]] tunnel diodes.


== Comparison of S-50 and S-52 ==
The S-50 is similar to the [[S-52]], but the output pulse amplitude of the S-50 is 400 mV, twice that of the S-52. 
The S-50's output tunnel diode is directly connected to the main pulse output connector. 
The S-52 has a 48-ohm resistor between the output tunnel diode and the main pulse output connector, resulting in a 2:1 voltage divider. 
Another difference between the S-50 and S-52 is the presence of a TRIG OUT on the front of the of S-50.  Both have PRETRIGGER OUT connectors. 
The pretrigger of the S-50 leads the main pulse by 75 ns, that of the S-52 by 85 ns. 
At the circuit level, the S-50 and S-52 differ significantly.  Both use a current switch to bias the output tunnel diode when
it is in the "armed" state.  The S-50 uses another tunnel diode to add a short pulse of current that "fires" the output tunnel diode.  The S-52 uses a [[snap-off diode]] to generate this firing pulse. 


== Comparison of S-50 and S-52 ==
Sequencing of events (arming the output diode, firing it, resetting it) is controlled by analog timing circuits in the S-50.  The S-52 uses a digital counter and a decoder to generate the internal control signals.
The S-50 is similar to the [[S-52]],
but the output pulse amplitude of the S-50 is 400mV,
twice that of the S-52. 
The S-50's output tunnel diode is directly connected
to the main pulse output connector. 
The S-52 has a 48-ohm resistor between the output tunnel diode
and the main pulse output connector,
resulting in a 2:1 voltage divider. 
Another difference between the
S-50 and S-52 is that the presence of a TRIG OUT
on the front of the of S-50. 
Both have PRETRIGGER OUT. 
The pretrigger of the S-50 leads the main pulse by 75ns. 
The pretrigger of the S-52 leads the main pulse by 85ns. 
At the circuit level, the S-50 and S-52 differ significantly.
Both use a current switch to bias the output tunnel diode when
it is in the "armed" state.  The S-50 uses another tunnel diode
to add a short pulse of current that "fires" the output tunnel diode.
The S-52 uses a [[snap-off diode]] to generate this firing pulse. 
Sequencing of events (arming the output diode, firing it, resetting it)
is controlled by analog timing circuits in the S-50.  The S-52 uses a  
digital counter and a decoder to generate the internal control signals.


==Specifications==


{| border="1" style="text-align: center;"
{| border="1" style="text-align: center;"
Line 40: Line 38:
|-
|-
! scope="col" | Risetime
! scope="col" | Risetime
| under 25ps
| under 25 ps
| under 25ps
| under 25 ps
|-
|-
! scope="col" | Amplitide
! scope="col" | Amplitide
| 400mV into 50 ohms
| 400 mV into 50 Ω
| 200mV into 50 ohms
| 200 mV into 50 Ω
|-
|-
! scope="row" | Output impedance
! scope="row" | Output impedance
| varies, not specified || 50 ohms
| varies, not specified || 50 Ω
|-
|-
! scope="row" | Sequencing of internal events
! scope="row" | Sequencing of internal events
Line 55: Line 53:
|-
|-
! scope="row" | Pretrigger lead time
! scope="row" | Pretrigger lead time
| 75ns
| 75 ns
| 85ns
| 85 ns
|-
|-
! scope="row" | Pretrigger to pulse jitter
! scope="row" | Pretrigger to pulse jitter
| 15ps
| 15 ps
| 10ns
| 10 ns
|-
|-
! scope="row" | Pulse repetition rate
! scope="row" | Pulse repetition rate
| 25kHz
| 25 kHz
| 120kHz
| 120 kHz
|-
|-
! scope="row" | Trigger (with pulse) output  
! scope="row" | Trigger (with pulse) output  
| yes, 200mV into 50 ohms
| yes, 200 mV into 50 Ω
| no
| no
|-
|-
Line 75: Line 73:
|}
|}


 
==Pictures==
* [http://w140.com/tek_s-50.pdf Tektronix S-50 Manual (46MB, PDF)]
* [http://w140.com/tek_s-series_sampling_heads.pdf Tektronix S-Series Sampling Heads (195MB, PDF)]
 


<gallery>
<gallery>
Line 85: Line 80:
Image:Tek s-50.JPG|front view
Image:Tek s-50.JPG|front view
</gallery>
</gallery>
[[Category:7000 and 3S series sampling heads]]