The Tektronix S-50 is a pulse generator head | {{Plugin Sidebar | | ||
with a | title=Tektronix S-50 | | ||
[[Connectors#SMA|SMA connector]]. The | summary=Pulse Generator | | ||
PRETRIG OUT and TRIG OUT signals use [[Connectors #BSM|BSM connectors]]. | image=Tek s-50.JPG | | ||
caption=S50 Head | | |||
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] | | |||
years=? – ? | | |||
manuals= | |||
* [http://w140.com/tek_s-50.pdf Tektronix S-50 Manual (46MB, PDF)] | |||
* [http://w140.com/tek_s-series_sampling_heads.pdf Tektronix S-Series Sampling Heads (195MB, PDF)] | |||
}} | |||
The Tektronix S-50 is a pulse generator head that produces 400 mV pulses with a rise time under 25 ps. The pulse output is an | |||
[[Connectors#SMA|SMA connector]]. The PRETRIG OUT and TRIG OUT signals use [[Connectors #BSM|BSM connectors]]. | |||
The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]]. | The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]]. | ||
The internal timing circuitry of the S-50 uses two [[152-0379-00]] tunnel diodes. | The internal timing circuitry of the S-50 uses two [[152-0379-00]] tunnel diodes. | ||
== Comparison of S-50 and S-52 == | |||
The S-50 is similar to the [[S-52]], but the output pulse amplitude of the S-50 is 400 mV, twice that of the S-52. | |||
The S-50's output tunnel diode is directly connected to the main pulse output connector. | |||
The S-52 has a 48-ohm resistor between the output tunnel diode and the main pulse output connector, resulting in a 2:1 voltage divider. | |||
Another difference between the S-50 and S-52 is the presence of a TRIG OUT on the front of the of S-50. Both have PRETRIGGER OUT connectors. | |||
The pretrigger of the S-50 leads the main pulse by 75 ns, that of the S-52 by 85 ns. | |||
At the circuit level, the S-50 and S-52 differ significantly. Both use a current switch to bias the output tunnel diode when | |||
it is in the "armed" state. The S-50 uses another tunnel diode to add a short pulse of current that "fires" the output tunnel diode. The S-52 uses a [[snap-off diode]] to generate this firing pulse. | |||
Sequencing of events (arming the output diode, firing it, resetting it) is controlled by analog timing circuits in the S-50. The S-52 uses a digital counter and a decoder to generate the internal control signals. | |||
Sequencing of events (arming the output diode, firing it, resetting it) | |||
is controlled by analog timing circuits in the S-50. The S-52 uses a | |||
digital counter and a decoder to generate the internal control signals. | |||
==Specifications== | |||
{| border="1" style="text-align: center;" | {| border="1" style="text-align: center;" | ||
Line 40: | Line 38: | ||
|- | |- | ||
! scope="col" | Risetime | ! scope="col" | Risetime | ||
| under | | under 25 ps | ||
| under | | under 25 ps | ||
|- | |- | ||
! scope="col" | Amplitide | ! scope="col" | Amplitide | ||
| | | 400 mV into 50 Ω | ||
| | | 200 mV into 50 Ω | ||
|- | |- | ||
! scope="row" | Output impedance | ! scope="row" | Output impedance | ||
| varies, not specified || | | varies, not specified || 50 Ω | ||
|- | |- | ||
! scope="row" | Sequencing of internal events | ! scope="row" | Sequencing of internal events | ||
Line 55: | Line 53: | ||
|- | |- | ||
! scope="row" | Pretrigger lead time | ! scope="row" | Pretrigger lead time | ||
| | | 75 ns | ||
| | | 85 ns | ||
|- | |- | ||
! scope="row" | Pretrigger to pulse jitter | ! scope="row" | Pretrigger to pulse jitter | ||
| | | 15 ps | ||
| | | 10 ns | ||
|- | |- | ||
! scope="row" | Pulse repetition rate | ! scope="row" | Pulse repetition rate | ||
| | | 25 kHz | ||
| | | 120 kHz | ||
|- | |- | ||
! scope="row" | Trigger (with pulse) output | ! scope="row" | Trigger (with pulse) output | ||
| yes, | | yes, 200 mV into 50 Ω | ||
| no | | no | ||
|- | |- | ||