36,733
edits
Jaredcabot (talk | contribs) (Added Programming Examples Software 063-1134-00 V1.2) |
No edit summary |
||
(7 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
'''TDS784A''' | |||
* [[Media:070-8991-02.pdf|TDS784A User 070-8991-02]] / <small>[[Media:070-8991-02 c2.pdf|Alternate copy]]</small> | |||
* [[Media:070-8992-03.pdf|TDS784A Service 070-8992-03]] | |||
* [[Media:070-9386-03.pdf|TDS700A Service 070-9386-03]] | |||
* [[Media:070-9721-02.pdf|TDS700A Service 070-9721-02]] | |||
* [[Media:070-8999-02.pdf|TDS784A Reference 070-8999-02]] / <small>[[Media:070-8999-02 c2.pdf|Alternate copy]]</small> | |||
* [[Media:070-9382-01.pdf|TDS700A Reference 070-9382-01]] | |||
* [[Media:070-8709-06.pdf|TDS700A Programmer 070-8709-06]] | |||
* [[Media:070-8709-07.pdf|TDS700A Programmer 070-8709-07]] | |||
* [[Media:070-9556-00.pdf|TDS784A etc Programmer 070-9556-00]] | |||
* [[Media:070-8990-04.pdf|TDS784A Performance Verification and Specifications 070-8990-04]] | |||
* [[Media:070-9384-01.pdf|TDS700A Performance Verification and Specifications 070-9384-01]] | |||
* [[Media:070-9473-01.pdf|TDS784A Firmware Field Upgrade TDS 7U01 070-9473-01]] | |||
* [[Media:070-9719-00.pdf|TDS700A Digitizing Oscilloscopes 070-9719-00]] | |||
'''TDS784C''' | |||
* [[Media:070-9861-00.pdf|TDS700C Reference 070-9861-00]] / <small>[[Media:070-9861-00 c2.pdf|Alternate copy]]</small> | |||
* [[Media:070-9869-00.pdf|TDS700C User 070-9869-00]] / <small>[[Media:070-9869-00 c2.pdf|Alternate copy]]</small> | |||
* [[Media:070-9874-02.pdf|TDS700C Technical Reference 070-9874-02]] | |||
* [[Media:070-9875-04.pdf|TDS700C Service 070-9875-04]] | |||
* [[Media:070-9876-00.pdf|TDS700C Programmers Manual 070-9876-00]] | |||
* [[Media:071-0090-01.pdf|TDS700C User Manual Supplement 071-0090-01]] / <small>[[Media:071-0090-01 c2.pdf|Alternate copy]]</small> | |||
'''TDS784D''' | |||
* [[Media:071-0130-00.pdf|TDS700D User Manual 071-0130-00]] | |||
* [[Media:071-0130-03.pdf|TDS700D User Manual 071-0130-03]] | |||
* [[Media:071-0134-00.pdf|TDS700D User Manual Japanese 071-0134-00]] | |||
* [[Media:071-0273-02.pdf|TDS700D User Manual Supplement 071-0273-02]] | |||
* [[Media:071-0273-03.pdf|TDS700D User Manual Supplement EN/FR/DE/KR/JP 071-0273-03]] | |||
* [[Media:071-0504-00.pdf|TDS700D Reference 071-0504-00]] | |||
* [[Media:071-0627-02.pdf|TDS700D Service 071-0627-02]] / <small>[[Media:071-0627-02 c2.pdf|Alternate copy]]</small> | |||
* [[Media:071-0630-03.pdf|TDS700D Performance Verification and Specifications 071-0630-03]] | |||
* [[Media:071-0875-00.pdf|TDSJIT1V2 Jitter Analysis Measurements Application 071-0875-00]] | |||
* [[Media:55W_11336_2.pdf|TDS700D Datasheet 55W_11336_2]] | |||
* [[Media:55W_11336_3.pdf|TDS700D Datasheet 55W_11336_3]] | |||
* [[Media:TDS700D_Datasheet_55W_11336_4.pdf|TDS700D Datasheet 55W_11336_4]] | |||
'''Common''' | |||
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]] | * [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]] | ||
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | * [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | ||
* [[Media:070-8567-01.pdf|Option 13 RS-232/Centronics Hardcopy Interface Instruction Manual 070-8567-01]] | |||
* [[Media:070-8582-01.pdf|Option 2F Advanced DSP Math Instruction Manual 070-8582-01]] | |||
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | * [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | ||
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] | * [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] | ||
Line 25: | Line 64: | ||
* [[Media:071-0375-02.pdf|TDXF2C, TDSXF3C, TDSXF4C, TDSXF1M2 & TDSXF1M4 Upgrades 071-0375-02]] | * [[Media:071-0375-02.pdf|TDXF2C, TDSXF3C, TDSXF4C, TDSXF1M2 & TDSXF1M4 Upgrades 071-0375-02]] | ||
* [[Media:071-0442-02.pdf|TDS500C/500D/600C/700C,D,L HDD Upgrade 071-0442-02]] | * [[Media:071-0442-02.pdf|TDS500C/500D/600C/700C,D,L HDD Upgrade 071-0442-02]] | ||
* [[Media:071-0581-00.pdf|TDSPSM1 Processor Specifications Measurements Application User Manual 071-0581-00]] | |||
* [[Media:071-0605-00.pdf|TDSCPM1 Communications Pulse Measurements Application 071-0605-00]] | * [[Media:071-0605-00.pdf|TDSCPM1 Communications Pulse Measurements Application 071-0605-00]] | ||
* [[Media:071-0606-00.pdf|TDSCEM1 Communications Eye-Diagram Measurements Application 071-0606-00]] | * [[Media:071-0606-00.pdf|TDSCEM1 Communications Eye-Diagram Measurements Application 071-0606-00]] | ||
* [[Media:071-0817-00.pdf|WSTRO, WSTROU & WSTRM WaveStar Software, AD007 GPIB-LAN Adapter, TDS3EM Ethernet Comms Module User Manual 071-0817-00]] | * [[Media:071-0817-00.pdf|WSTRO, WSTROU & WSTRM WaveStar Software, AD007 GPIB-LAN Adapter, TDS3EM Ethernet Comms Module User Manual 071-0817-00]] | ||
* [[Media:071-1140-03.pdf|WaveStar Software, Wavestar Reader, AD007 GPIB-LAN Adapter Software Solutions Installation 071-1140-03]] | * [[Media:071-1140-03.pdf|WaveStar Software, Wavestar Reader, AD007 GPIB-LAN Adapter Software Solutions Installation 071-1140-03]] | ||
* [[Media:55W_12028_0.pdf|TDSPWR1 Power Measurement Software Datasheet 55W_12028_0]] | |||
* [[Media:55W_12056_0.pdf|TDSDDM1 Disk Drive Measurement Software Datasheet 55W_12056_0]] | |||
}} | }} | ||
The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s four-channel digital storage scope with a color screen.<br> | The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s four-channel digital storage scope with a color screen.<br> | ||
There are four variants, all with the same specs but different hardware/software loads − TDS784A, B, C & D. Of these, the C and D models are the least problematic and most sought-after. | There are four variants, all with the same specs but different hardware/software loads − TDS784A, B, C & D. Of these, the C and D models are the least problematic and most sought-after. | ||
Line 92: | Line 101: | ||
<br> | <br> | ||
* [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (ZIP) | * [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (ZIP) | ||
* [[Media: | * [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP) | ||
* [[Media: | * [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP) | ||
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP) | |||
* [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP 066-0119-00]] (ZIP) | * [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP 066-0119-00]] (ZIP) | ||
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP) | * [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP) | ||
* [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP) | * [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP) | ||
* [[Media: | * [[Media:066-0165-00.zip|Tektronix TDS500C/700C Custom Masks 066-0165-00]] (ZIP) | ||
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP) | |||
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP) | |||
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP) | |||
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP) | |||
* [[Media:066-0183-00.zip|TDS Sandisk Hard Disk Patch Utility 066-0183-00]] (ZIP) | |||
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP) | |||
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP) | |||
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP) | |||
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP) | |||
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP) | |||
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP) | |||
* [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP) | |||
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124'' | * [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124'' | ||
Line 193: | Line 215: | ||
It is also worth noting the [[TDS754]] and TDS784 series are nearly identical, with the differences being in front-panel cosmetics and the presence (754) or absence (784) of a few capacitors on the acquisition board. The only other difference is the position of instrument ID jumpers, also on the acquisition board. In fact, it is entirely possible to convert a 754 to a 784 (see the 'Links' section). | It is also worth noting the [[TDS754]] and TDS784 series are nearly identical, with the differences being in front-panel cosmetics and the presence (754) or absence (784) of a few capacitors on the acquisition board. The only other difference is the position of instrument ID jumpers, also on the acquisition board. In fact, it is entirely possible to convert a 754 to a 784 (see the 'Links' section). | ||
Note that any kind of firmware updating of the 784 (and most other similar TDS scopes) requires very specific equipment, starting with an older computer (ISA slots required) running MS-DOS 5.x or later as well as Windows 98SE. To interface with the scope, you will need a National Instruments PC/GPIB-II ISA-based (8-bit) GPIB board or a National Instruments AT-GPIB (16-bit) board and appropriate drivers. The software required to do the update (Tektool or Tekfwtool) also runs under DOS (or a DOS box in Windows 98). Information on this tool can be found in the ''Links'' section in the thread describing firmware updates. | <del>Note that any kind of firmware updating of the 784 (and most other similar TDS scopes) requires very specific equipment, starting with an older computer (ISA slots required) running MS-DOS 5.x or later as well as Windows 98SE. To interface with the scope, you will need a National Instruments PC/GPIB-II ISA-based (8-bit) GPIB board or a National Instruments AT-GPIB (16-bit) board and appropriate drivers. The software required to do the update (Tektool or Tekfwtool) also runs under DOS (or a DOS box in Windows 98). Information on this tool can be found in the ''Links'' section in the thread describing firmware updates.</del><br> | ||
Using the 'Unified Tektool', a firmware update can be achieved using a standard USB-GPIB adapter [https://www.eevblog.com/forum/repair/unified-tektool-released-!-(firmware-flash-tools-for-old-tds-series)/msg3758918/#msg3758918 as detailed in this link]. Be sure to backup BOTH your firmware AND NVRAM before writing the new firmware in!<br> | |||
If the new firmware does not work in your scope, a full clear of the firmware and NVRAM and then loading your backed up firmware and NVRAM back in will have it working again on the original firmware. | |||
Actual calibration requires the above computer, the specific PC/GPIB-II card and drivers and an MS-DOS environment. You will also need an Analogic/Data Precision model 8200 DC voltage standard and a levelled sine-wave generator capable of going up to 1 GHz (if you're just doing a 754, you can get away with a 500 MHz top end). Naturally, Tek used the [[SG503]] and [[SG504]]. | Actual calibration requires the above computer, the specific PC/GPIB-II card and drivers and an MS-DOS environment. You will also need an Analogic/Data Precision model 8200 DC voltage standard and a levelled sine-wave generator capable of going up to 1 GHz (if you're just doing a 754, you can get away with a 500 MHz top end). Naturally, Tek used the [[SG503]] and [[SG504]]. | ||
Line 212: | Line 237: | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|TDS784A}} | |||
{{Parts|TDS784B}} | |||
{{Parts|TDS784C}} | |||
{{Parts|TDS784D}} | |||
[[Category:TDS700 series scopes]] | [[Category:TDS700 series scopes]] |