TDS784: Difference between revisions

304 bytes added ,  9 January 2018
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
{{Oscilloscope Sidebar |
title=Tektronix TDS784 |
image=TDS784D.jpg |
caption=Tektronix TDS784D |
introduced=(?) |
discontinued=(?) |
summary=1 GHz, 4 GS/s 4-ch-channel digital scope |
manuals=
[[Category:Manual needed]] ''please add''
}}
The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s quad-channel digital storage scope.
The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s quad-channel digital storage scope.
There are four variants, all with the same specs but different hardware/software loads: TDS784A, B, C & D. Of these, the C and D models are the least problematic and most sought-after.
There are four variants, all with the same specs but different hardware/software loads: TDS784A, B, C & D. Of these, the C and D models are the least problematic and most sought-after.


==Specifications==
===Acquisition===
* Sample rate: 1 channel @ 4 GS/s, 2 channels @ 2 GS/s, 3 or 4 channels @ 1 GS/s
* Analog bandwidth : 1 mV/div: 500 MHz, 2 mV/div: 600 MHz, 5 mV/div: 750 MHz, >= 10 mV/div: 1 GHz
* Resolution: 8-bit
* Record lengths : 50k samples per channel (500k with option 1M)
* Modes: sample, envelope, average, high-resolution, and peak-detect
===Misc===
* Display: color; Zoom
* Trigger modes Include: edge, logic, and pulse. Video trigger, with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat)
* Storage: 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups
* Units with option HD present (requires additional hardware) have a hard disk drive
* I/O: Full GPIB programmability
* Hardcopy output using [[GPIB]], [[RS-232]], or Centronics ports
==Links==
* [http://www.eevblog.com/forum/testgear/conversion-of-500mhz-tds744a-to-1ghz-tds784a/ Conversion of 500MHz TDS744A to 1GHz TDS784A]
* [http://forum.tek.com/viewtopic.php?f=568&t=140017/ Tek Forum thread on recovering the unit from a bricked state]
* [http://forum.tek.com/viewtopic.php?f=568&t=139999&hilit=TDS784/ Tek Forum thread on firmware updating]
* [http://forum.tek.com/viewtopic.php?f=568&t=138168&hilit=TDS784/ Tek Forum thread on backing up and restoring calibration data]
* [http://www.simmconnlabs.com/2001/9001.html/ Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes]
* [http://www.eevblog.com/forum/testgear/hackingupgrading-old-scope-(tds754d)/ EEVBlog Forum thread on TDS options and how to enable them]
==Internals==
For units with serial numbers prior to B04xxxx, the latest known firmware revision is 6.6e. For units with serial numbers B04xxxx and above, the last known version is 7.4e. Note that, due to differences in acquisition and CPU board hardware, release 7.4e will not work in the earlier revision units. Early revision units may have a CPU board P/N of 679-4172-00. The later revision is 679-4349-00.
For units with serial numbers prior to B04xxxx, the latest known firmware revision is 6.6e. For units with serial numbers B04xxxx and above, the last known version is 7.4e. Note that, due to differences in acquisition and CPU board hardware, release 7.4e will not work in the earlier revision units. Early revision units may have a CPU board P/N of 679-4172-00. The later revision is 679-4349-00.


It is also worth noting the TDS754 and TDS784 series are nearly identical, with the differences being in front-panel cosmetics and the presence (754) or absence (784) of a few capacitors on the acquisition board. The only other difference is the position of instrument ID jumpers, also on the acquisition board. In fact, it is entirely possible to convert a 754 to a 784 (see the 'Links' section).
It is also worth noting the [[TDS754]] and TDS784 series are nearly identical, with the differences being in front-panel cosmetics and the presence (754) or absence (784) of a few capacitors on the acquisition board. The only other difference is the position of instrument ID jumpers, also on the acquisition board. In fact, it is entirely possible to convert a 754 to a 784 (see the 'Links' section).


Note that any kind of firmware updating of the 784 (and most other similar TDS O-Scopes) requires very specific equipment, starting with an older computer (ISA slots required) running MS-DOS 5.x or later as well as Windows 98SE. To interface with the 'scope, you will need a National Instruments PC/GPIB-II ISA-based (8-bit) GPIB board or a National Instruments AT-GPIB (16-bit) board and appropriate drivers. The software required to do the update (Tektool or Tekfwtool) also runs under DOS (or a DOS box in Windows 98). Information on this tool can be found in the 'Links' section in the thread describing firmware updates.
Note that any kind of firmware updating of the 784 (and most other similar TDS O-Scopes) requires very specific equipment, starting with an older computer (ISA slots required) running MS-DOS 5.x or later as well as Windows 98SE. To interface with the 'scope, you will need a National Instruments PC/GPIB-II ISA-based (8-bit) GPIB board or a National Instruments AT-GPIB (16-bit) board and appropriate drivers. The software required to do the update (Tektool or Tekfwtool) also runs under DOS (or a DOS box in Windows 98). Information on this tool can be found in the 'Links' section in the thread describing firmware updates.
Line 20: Line 55:
* [http://w140.com/TDS640A_Programmer_EN.pdf Tektronix TDS 410A, 420A, 460A, 520A, 524A, 540A, 544A, 620A, 640A, 644A, 684A, 744A & 784A Programmer Manual 070-8709-07]
* [http://w140.com/TDS640A_Programmer_EN.pdf Tektronix TDS 410A, 420A, 460A, 520A, 524A, 540A, 544A, 620A, 640A, 644A, 684A, 744A & 784A Programmer Manual 070-8709-07]


==Specifications==
===Acquisition===
* Sample rate :
** 4 GS/s when acquiring 1 channel
** 2 GS/s when acquiring 2 channels,
** 1 GS/s when acquiring 3 or 4 channels
* Analog bandwidth : 1 mV/div: 500 MHz, 2 mV/div: 600 MHz, 5 mV/div: 750 MHz, >= 10 mV/div: 1 GHz
* 4 Channels, 8-bit resolution
* Record lengths : 50k samples per channel (500k with option 1M)
* Modes : sample, envelope, average, high-resolution, and peak-detect
===Misc===
* Display : color; Zoom
* Trigger modes Include: edge, logic, and pulse. Video trigger, with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat)
* Storage 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups
* Units with option HD present (requires additional hardware) have a hard disk drive.
* I/O Full GPIB programmability.
* Hardcopy output using GPIB, RS-232, or Centronics ports
==Links==
* [http://www.eevblog.com/forum/testgear/conversion-of-500mhz-tds744a-to-1ghz-tds784a/ Conversion of 500MHz TDS744A to 1GHz TDS784A]
* [http://forum.tek.com/viewtopic.php?f=568&t=140017/ Tek Forum thread on recovering the unit from a bricked state]
* [http://forum.tek.com/viewtopic.php?f=568&t=139999&hilit=TDS784/ Tek Forum thread on firmware updating]
* [http://forum.tek.com/viewtopic.php?f=568&t=138168&hilit=TDS784/ Tek Forum thread on backing up and restoring calibration data]
* [http://www.simmconnlabs.com/2001/9001.html/ Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes]
* [http://www.eevblog.com/forum/testgear/hackingupgrading-old-scope-(tds754d)/ EEVBlog Forum thread on TDS options and how to enable them.]


[[Category:TDS series scopes]]
[[Category:TDS series scopes]]
[[Category:GPIB interface]]
[[Category:RS-232 interface]]
[[Category:Parallel printer interface]]