a ×10 probe will connect this pad to ground through 11 kΩ, or short it to ground when the Identify button  
a ×10 probe will connect this pad to ground through 11 kΩ, or short it to ground when the Identify button  
is pressed — see [[7000 series readout system]] for details).  The smaller pads carry +15 V, +5 V, −5 V and −15 V
is pressed — see [[7000 series readout system]] for details).  The smaller pads carry +15 V, +5 V, −5 V and −15 V
power, an offset voltage supplied and controlled by the mainframe, and a clock/data signal pair for serial
power, an offset voltage (-1 V to +1 V) supplied and controlled by the mainframe, and a clock/data signal pair for serial
communication between the mainframe and "smart" probes.  Probes are allowed to draw max. 1.25 W, max. 75 mA from the ±5 V rails, and max. 25 mA from the ±15 V rails.  
communication between the mainframe and "smart" probes.  Probes are allowed to draw max. 1.25 W, max. 75 mA from the ±5 V rails, and max. 25 mA from the ±15 V rails.  