120-0308-00
(Redirected from 120-308)
The Tektronix 120-0308-00 is a high voltage transformer used in the 543B, 544, 545B, 546 and 547.
A common failure is hot running due to dielectric loss. The potting is not moisture resistant.
Data
Pictures
-
winding data for 120-308
Used in
Some instruments using part 120-0308-00
Instrument | Manufacturer | Class | Model | Description | Introduced |
---|---|---|---|---|---|
543B | Tektronix | Oscilloscope | 543B | 30 MHz oscilloscope | 1964 |
544 | Tektronix | Oscilloscope | 544 | 50 MHz oscilloscope | 1964 |
545B | Tektronix | Oscilloscope | 545B | 30 (33) MHz oscilloscope | 1964 |
546 | Tektronix | Oscilloscope | 546 | 50 MHz oscilloscope | 1964 |
547 | Tektronix | Oscilloscope | 547 | 50 MHz oscilloscope | 1964 |