P: Difference between revisions

Jump to navigation Jump to search
285 bytes added ,  31 August 2014
template
No edit summary
(template)
Line 1: Line 1:
The Tektronix Type P plug-in is a calibration aid [[introduced in 1959]]  
{{Plugin Sidebar 2 |
title=Tektronix Type P |
summary=Calibration aid |
series=[[500-series scopes]]|
image=Tek type p.jpg |
caption=Tek Type P |
introduced=1959 |
discontinued=1963 |
manuals=
* [http://bama.edebris.com/manuals/tek/p/ Tektronix Type P Manual (PDF)]
* [http://w140.com/tek_fcp/tek_type_p_factory_cal_proc.pdf Tektronix Type P Factory Calibration Procedure (PDF)]
}}
The '''Tektronix Type P''' plug-in is a calibration aid [[introduced in 1959]]  
for [[500-series scopes]].   
for [[500-series scopes]].   
It applies a fast (4 nanosecond risetime) voltage step to the mainframe vertical amplifier,  
It applies a fast (4 nanosecond risetime) voltage step to the mainframe vertical amplifier,  
via plug-in connector pins 1 and 3.   
via plug-in connector pins 1 and 3.   
It's used when adjusting the peaking coils and the [[delay line]]. 
The Type P is designed to simulate a perfectly-adjusted Type [[K]]  
The Type P is designed to simulate a perfectly-adjusted Type [[K]]  
plug-in being driven by a Type [[107]] square-wave generator.   
plug-in being driven by a Type [[107]] square-wave generator, and is
used when adjusting the peaking coils and the [[delay line]].   
The idea is to calibrate a mainframe using Type P,  
The idea is to calibrate a mainframe using Type P,  
then use this mainframe and a 107 to calibrate other plug-ins.
then use this mainframe and a 107 to calibrate other plug-ins.
Line 13: Line 26:
The selenium rectifier in the Type P has four sections and full-wave rectifies
The selenium rectifier in the Type P has four sections and full-wave rectifies
the 6.3 VAC that is supplied by the scope mainframe on pins 13 and 14.   
the 6.3 VAC that is supplied by the scope mainframe on pins 13 and 14.   
The 120Hz (assuming 60Hz mains) component of the full-wave rectified waveform
The 120 Hz (assuming 60 Hz mains) component of the full-wave rectified waveform
is applied to the coil of the mercury switch to drive the opening and closing
is applied to the coil of the mercury switch to drive the opening and closing
of the contacts.  An adjustable fraction of the DC component of the full-wave  
of the contacts.  An adjustable fraction of the DC component of the full-wave  
Line 23: Line 36:
from Type 53/54[[C]] to Type [[CA]].  It was dropped after 1963, replaced by the [[TU-7]].
from Type 53/54[[C]] to Type [[CA]].  It was dropped after 1963, replaced by the [[TU-7]].


* [http://bama.edebris.com/manuals/tek/p/ Tektronix Type P Manual (PDF)]
==Pictures==
* [http://w140.com/tek_fcp/tek_type_p_factory_cal_proc.pdf Tektronix Type P Factory Calibration Procedure (PDF)]


<gallery>
<gallery>
Line 31: Line 43:
Image:Type_p_schem.png
Image:Type_p_schem.png
</gallery>
</gallery>
[[Category:500 series plugins]]
[[Category:Calibration fixtures]]

Navigation menu