DIGITAL MULTIMETER
DIRECT CURRENT VOLTS
Range:  0.1v to 1000v
Input Resistance: 10MΩ
Accuracy,  0.1v & 1v:  ±0.1%, ±3 counts; 10v & 100v: ±0.15%, ±1 count; 1000v: ±0.2%, ±1 count
 
TRUE RMS VOLTS
0.1v: ±2.5% (DC); ±1.5% (40 Hz – 4KHz); ±3.5% (4KHz – 40KHz)
1, 10, 100v:  ±2% (DC); ±1% (40Hz – 40KHz)
1000v:  ±2% (DC); ±1% (40 Hz – 4KHz); ±2% (4KHz – 40KHz)
 
DC & RMS CURRENT
0.1mA = 1000Ωs; 1mA = 100Ω; 10mA = 10.2Ω; 100mA = 1.2Ω; 1000mA = 0.3Ω
 
DC CURRENT
0.1mA:  ±0.5%, ±3 counts; 1mA – 1000mA: ±0.25%, ±3 counts
 
TRUE RMS CURRENT
0.1mA:  ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40Hz – 4KHz); ±4.5%,±5 counts (4KHz - 40KHz)
1mA – 1000mA: ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40Hz – 4KHz); ±3.5%,±5 counts (4KHz - 40KHz)
 
RESISTANCE
1KΩ: ±0.5%, ±3 counts; 10KΩ – 1MΩ:  ±0.5%, ±1 count; 10MΩ: ±1%, ±1 count
 
OSCILLOSCOPE
VERTICAL:
5mv – 100V/DIV, ±3%, DC – 400KHz (5mV – 10mV/DIV); DC – 1MHz (20mV – 100v/DIV
5µA – 100mA/DIV, ±3%, DC – 200KHz (5µA – 10µA/DIV); DC – 400KHz (20µA – 200mA/DIV)
 
Input resistance:  10MΩ, 150pF (5mV – 1V/DIV); 100pf (2V – 100V/DIV)
 
Risetime:  875ns (5mV – 10mV/DIV); 350ns (20mV – 100v/DIV)
 
HORIZONTAL:
SWEEP: 500ms – 2µs/DIV, ±5% (magnified or unmagnified)
 
BATTERIES:
2 X “D” NiCd cells
Typical operating time as maximum intensity after full charge cycle:  3.5 hours
Charge time:  16 hours
 
MAINS OPERATION:
90 – 136vac, 48 – 62 Hz (Option 1: 180 – 250 vdc or 180 – 250 vac, 48 – 62 Hz)
Power consumption:  Less than 8 watts