{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar |
title=Tektronix 524 |
title=Tektronix 524 |
summary=TV scope |
summary=TV waveform monitoring scope |
image=Tek 524 trace.jpg |
image=Tek 524 trace.jpg |
caption=Tek 524 |
caption=Tek 524 |
Line 9: Line 9:
* [http://bama.edebris.com/download/tek/524ad/Tek%20524AD.pdf Tektronix 524AD Manual (PDF)]
* [http://bama.edebris.com/download/tek/524ad/Tek%20524AD.pdf Tektronix 524AD Manual (PDF)]
}}
}}
The '''Tektronix 524''' is an oscilloscope [[introduced in 1953]] for monitoring television waveforms.  It is a monolithic oscilloscope.   
The '''Tektronix 524''' is an oscilloscope [[introduced in 1953]] for monitoring television waveforms.  It is a monolithic oscilloscope.  It was designed by [[Cliff Moulton]].


Interestingly, the 524 appears on page 33 of the [http://www.americanradiohistory.com/Archive-Catalogs/RCA-Test-Equip-1966.pdf 1966 RCA Test Equipment Catalog].
Interestingly, the 524 appears on page 33 of the [http://www.americanradiohistory.com/Archive-Catalogs/RCA-Test-Equip-1966.pdf 1966 RCA Test Equipment Catalog].
{{MissingSpecs}}


The 524 weighs 61 pounds, uses 500 watts, and has a [[thermal cutoff]].  It uses [[selenium rectifiers]] in the low-voltage  
The 524 weighs 61 pounds, uses 500 watts, and has a [[thermal cutoff]].  It uses [[selenium rectifiers]] in the low-voltage  
Line 19: Line 21:
but P7 and P11 phosphors were also available.
but P7 and P11 phosphors were also available.


==Internals==
The vertical signal path of the 524 is similar to that of the [[514]].   
The vertical signal path of the 524 is similar to that of the [[514]].   
They have similar front-ends and similar [[distributed amplifier|distributed vertical output amplifiers]].
They have similar front-ends and similar [[distributed amplifier|distributed vertical output amplifiers]].
Line 29: Line 32:
most importantly, a non-retriggerable multivibrator.   
most importantly, a non-retriggerable multivibrator.   
The multivibrator is triggered by the vertical sync of the NTSC waveform.
The multivibrator is triggered by the vertical sync of the NTSC waveform.
After being triggered, it is not triggerable again for about about 25ms, so it
After being triggered, it is not triggerable again for about about 25 ms, so it
misses the vertical sync of the next interlaced field and instead triggers on  
misses the vertical sync of the next interlaced field and instead triggers on  
the vertical sync of one following that.  So it consistently shows the "even" field
the vertical sync of one following that.  So it consistently shows the "even" field