P6013: Difference between revisions

Jump to navigation Jump to search
490 bytes added ,  29 September 2014
descriptions
(New page: * [http://w140.com/kurt/tektronix_p6013a.pdf Tektronix P6013A Manual (PDF)])
 
(descriptions)
Line 1: Line 1:
[[Image:P6013A.jpg|thumb|350px|right|P6013A]]
The '''Tektronix P6013''' is a 1000 × high voltage probe for oscilloscopes.
==Specifications==
{{BeginSpecs}}
{{Spec | Input impedance | 100 MΩ // 3 pF }}
{{Spec | Attenuation    | 1 : 1000 }}
{{Spec | Frequency range | 50 MHz }}
{{Spec | Input voltage  | 12 kV max. (derated to 5 kV at 100 kHz) }}
{{Spec | Connector      | UHF }}
{{EndSpecs}}
==Manuals==
* [http://w140.com/kurt/tektronix_p6013a.pdf Tektronix P6013A Manual (PDF)]
* [http://w140.com/kurt/tektronix_p6013a.pdf Tektronix P6013A Manual (PDF)]
[[Category:1 MOhm Oscilloscope Probes]]
[[Category:High Voltage Probes]]

Navigation menu