The R116 is a pulse generator [[introduced in 1968]] for use with automated measurement systems such as the [[240]] and [[R250]].
[[File:Tek-r116.jpg|right|350px]]
The R116 uses a [[1N3716]] tunnel diode.
The '''Tektronix R116''' is a programmable pulse generator [[introduced in 1968]] for use with automated measurement systems such as the [[240]] and [[R250]].


The R116 uses a [[1N3716]] tunnel diode to produce pulses. 
==Manuals==
* [http://w140.com/tek_r116_description.pdf Description of R116 from Tektronix Automated Testing Systems book (PDF)]
* [http://w140.com/tek_r116_description.pdf Description of R116 from Tektronix Automated Testing Systems book (PDF)]
* [http://bama.edebris.com/download/tek/r116late/tek%20r116%20early.v6.pdf Tektronix R116 Manual (early, PDF)]
* [http://bama.edebris.com/download/tek/r116late/tek%20r116%20early.v6.pdf Tektronix R116 Manual (early, PDF)]
* [http://bama.edebris.com/download/tek/r116late/tek%20r116%20late.v6.pdf Tektronix R116 Manual (late, PDF)]
* [http://bama.edebris.com/download/tek/r116late/tek%20r116%20late.v6.pdf Tektronix R116 Manual (late, PDF)]
Line 9: Line 11:
* [http://w140.com/tek_r116_1968_catalog.pdf Tektronix R116 in 1968 Catalog (PDF)]
* [http://w140.com/tek_r116_1968_catalog.pdf Tektronix R116 in 1968 Catalog (PDF)]


{{BeginSpecs}}
{{Spec | Pulse period | 100 ns to 11 ms (± 3%)}}
{{Spec | Pulse delay  | 50 ns to 550 μs (± 3% + 10 ns)}}
{{Spec | Pulse width  | 50 ns to 550 μs (± 3% + 10 ns)}}
{{Spec | Rise time    | 10 ns to 110 μs (± 10% below in 1 ns and 10 ns ranges, ± 5% above)}}
{{Spec | Fall time    | 10 ns to 110 μs (± 10% below in 1 ns and 10 ns ranges, ± 5% above)}}
{{Spec | Pulse amplitude | 0.4 V to 10 V into 50 Ω, positive or negative (± 3% + 15/25/50 mV) }}
{{Spec | Pulse offset | 0 to ±5 V in 3 ranges (± 5% + 200 mV)}}
{{Spec | Features |
* "Programmable"
* Double pulse mode
}}
{{EndSpecs}}
The R116 has a programming connector in the back.  Eight operating parameters can be programmed digitally (by switch closure):
* Trigger Source
* Mode
* Period Range
* Delay or Burst Time Range
* Width Range
* Amplitude Range
* Polarity
* Rise Time/Fall Time Range
Seven more parameters are controlled by connecting external resistances:
* Period Multiplier
* Delay or Burst Time Multiplier
* Width Multiplier
* Amplitude Multiplier
* DC Offset
* Rise Time Multiplier
* Fall Time Multiplier