39,660
edits
No edit summary |
(specs, year) |
||
Line 1: | Line 1: | ||
The P6019 and [[P6020]] split-core AC current probes were introduced in | The P6019 and [[P6020]] split-core AC current probes were introduced in | ||
1966 together with passive terminations and | 1966 together with passive terminations and the [[134|Type 134]] amplifier. | ||
134. | |||
The probes had no internal frequency compensation components, | The probes had no internal frequency compensation components, | ||
contrary to their 1969 successor types P6021 and P6022. | contrary to their 1969 successor types [[P6021]] and [[P6022]]. | ||
==Specifications== | |||
{| class="wikitable" | |||
! | |||
! P6019 passive | |||
! P6019 + [[134]] | |||
! P6020 passive | |||
! P6020 + [[134]] | |||
|- | |||
! Sensitivity | |||
| 2 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) | |||
| 1 mA/mV or 10 mA/mV || 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) | |||
|- | |||
! Bandwidth (-3 dB) | |||
| 60 MHz @ 10 mA/mV || > 40 MHz | |||
| 200 MHz @ 10 mA/mV || > 70 MHz | |||
|- | |||
! LF limit (-3 dB) | |||
| 450 Hz @ 2 mA/mV, 120 Hz @ 10 mA/mV || < 12 Hz | |||
| 6500 Hz @ 1 mA/mV, 775 Hz @ 10 mA/mV || < 50 Hz | |||
|- | |||
! Maximum current | |||
| colspan="2" align="center" | 15 A<sub>p-p</sub> | |||
| colspan="2" align="center" | 6 A<sub>p-p</sub> | |||
|} | |||
==Links== | ==Links== | ||
Line 13: | Line 37: | ||
* [http://w140.com/P6019-P6020.djvu Tektronix P6019 / P6020 Manual (DjVu)] | * [http://w140.com/P6019-P6020.djvu Tektronix P6019 / P6020 Manual (DjVu)] | ||
''The djvu-file contains a compilation of scans from two editions of the P6019/P6020 manual.'' | ''The djvu-file contains a compilation of scans from two editions of the P6019/P6020 manual.'' | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] | ||
[[Category:Introduced in 1966]] |