{{Spec | ''Multimeter Section'' | <hr /> }}
{{SpecGroup | ''Multimeter Section'' }}
{{Spec | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy,  0.1 V & 1 V:  ±0.1%, ±3 counts; 10 V & 100 V: ±0.15%, ±1 count; 1000 V: ±0.2%, ±1 count}}
{{Spec | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy,  0.1 V & 1 V:  ±0.1%, ±3 counts; 10 V & 100 V: ±0.15%, ±1 count; 1000 V: ±0.2%, ±1 count}}
{{Spec | True RMS Volts | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy, 0.1 V: ±2.5% (DC); ±1.5% (40 Hz – 4 KHz); ±3.5% (4 KHz – 40 KHz);  1, 10, 100 V:  ±2% (DC); ±1% (40 Hz – 40 KHz); 1000 V:  ±2% (DC); ±1% (40 Hz – 4KHz); ±2% (4 KHz – 40 KHz) }}
{{Spec | True RMS Volts | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy, 0.1 V: ±2.5% (DC); ±1.5% (40 Hz – 4 KHz); ±3.5% (4 KHz – 40 KHz);  1, 10, 100 V:  ±2% (DC); ±1% (40 Hz – 40 KHz); 1000 V:  ±2% (DC); ±1% (40 Hz – 4KHz); ±2% (4 KHz – 40 KHz) }}
Line 25: Line 25:
{{Spec | Current range input resistance | 0.1 mA: 1000 Ω; 1 mA: 100 Ω; 10 mA: 10.2 Ω; 100 mA: 1.2 Ω; 1000 mA: 0.3 Ω }}
{{Spec | Current range input resistance | 0.1 mA: 1000 Ω; 1 mA: 100 Ω; 10 mA: 10.2 Ω; 100 mA: 1.2 Ω; 1000 mA: 0.3 Ω }}
{{Spec | Resistance | 1 KΩ: ±0.5%, ±3 counts; 10 KΩ – 1 MΩ:  ±0.5%, ±1 count; 10 MΩ: ±1%, ±1 count }}
{{Spec | Resistance | 1 KΩ: ±0.5%, ±3 counts; 10 KΩ – 1 MΩ:  ±0.5%, ±1 count; 10 MΩ: ±1%, ±1 count }}
{{Spec | ''Oscilloscope Section'' | <hr />}}
{{SpecGroup | ''Oscilloscope Section'' }}
{{Spec | Voltage ranges | 5 mV/Div to  – 100 V/Div, ±3% }}
{{Spec | Voltage ranges | 5 mV/Div to  – 100 V/Div, ±3% }}
{{Spec | Bandwidth (Voltage) | DC – 1 MHz (at 10 mV/Div and below, 400 kHz) }}
{{Spec | Bandwidth (Voltage) | DC – 1 MHz (at 10 mV/Div and below, 400 kHz) }}