7104: Difference between revisions

Jump to navigation Jump to search
No change in size ,  25 September 2015
no edit summary
No edit summary
No edit summary
Line 118: Line 118:
File:Tek7104-ristetime-100hz.jpg          | Rise time measurement.  150 ps risetime pulse from [[067-0587-02]] at 100 Hz repetition rate.  Measured 240 ps (corrected for 150 ps fixture rise time: 190 ns = 1.8 GHz)
File:Tek7104-ristetime-100hz.jpg          | Rise time measurement.  150 ps risetime pulse from [[067-0587-02]] at 100 Hz repetition rate.  Measured 240 ps (corrected for 150 ps fixture rise time: 190 ns = 1.8 GHz)
File:Tek7104-ristetime-1000hz.jpg        | Rise time measurement as before, 1000 Hz repetition rate at same brightness settings.
File:Tek7104-ristetime-1000hz.jpg        | Rise time measurement as before, 1000 Hz repetition rate at same brightness settings.
File:Tek7104-200ps-singleshot.jpg        | 7104 recording a single shot pulse (from [[067-0587-02]]) at 200 ps/Div.  Camera: Nikon D7100,  50 mm f/1.4, ISO 3200, 1/2 s.  CRT filter not removed.
File:Tek7104-200ps-singleshot.jpg        | 7104 recording a single shot pulse (from [[067-0587-02]]) at 200 ps/Div.  Camera: Nikon D7000,  50 mm f/1.4, ISO 3200, 1/2 s.  CRT filter not removed.
File:Tek7104-200ps-singleshot-sin1-1g.jpg | 7104 recording 1 GHz sine, single shot at 200 ps/Div.  Camera: Nikon D7100,  50 mm f/1.4, ISO 3200, 1/2 s.  CRT filter not removed.  CRT amplification loss is evident around the center line.
File:Tek7104-200ps-singleshot-sin1-1g.jpg | 7104 recording 1 GHz sine, single shot at 200 ps/Div.  Camera: Nikon D7000,  50 mm f/1.4, ISO 3200, 1/2 s.  CRT filter not removed.  CRT amplification loss is evident around the center line.
File:Tek7104-superluminal-beam.jpg        |  [https://web.archive.org/web/20110926020847/http://www.oregonlive.com/silicon-forest/index.ssf/2011/09/a_tektronix_oscilloscope_that.html Faster-than-light] beam on 7104?  Using a [[067-0587-02]] calibration fixture at maximum amplitude produces this trace spanning 1.2 Div horizontally at 200 ps/Div and 8 Div vertically.  Trace length is (1.2² + 8²)<sup>½</sup> × 8.5 mm = 68.8 mm, travelled in 1.2 × 200 ps = 240 ps.  Apparent speed is therefore 68.8×10<sup>-3</sup> / 240×10<sup>-12</sup> m/s or 2.86×10<sup>8</sup> m/s.  95.6% c<sub>0</sub> - a '''very''' near miss ...
File:Tek7104-superluminal-beam.jpg        |  [https://web.archive.org/web/20110926020847/http://www.oregonlive.com/silicon-forest/index.ssf/2011/09/a_tektronix_oscilloscope_that.html Faster-than-light] beam on 7104?  Using a [[067-0587-02]] calibration fixture at maximum amplitude produces this trace spanning 1.2 Div horizontally at 200 ps/Div and 8 Div vertically.  Trace length is (1.2² + 8²)<sup>½</sup> × 8.5 mm = 68.8 mm, travelled in 1.2 × 200 ps = 240 ps.  Apparent speed is therefore 68.8×10<sup>-3</sup> / 240×10<sup>-12</sup> m/s or 2.86×10<sup>8</sup> m/s.  95.6% c<sub>0</sub> - a '''very''' near miss ...
</gallery>
</gallery>

Navigation menu