39,552
edits
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The '''Tektronix CT-4''' is a passive high-current transformer used to extend the range of [[A6302]], [[A6302XL]], [[A6312]], [[TCP202]] or [[P6021]] oscilloscope current probes to up to 2 kA. | |||
The probe can be inserted in either of two slots, with 20:1 or 1000:1 current transformation resulting. | |||
{{BeginSpecs}} | |||
{{Spec | Maximum continuous current | 2,000 A }} | |||
{{Spec | Maximum peak current | 20,000 A }} | |||
{{Spec | Bandwidth | | |||
* With TCP202 or A6302/A6312: 0.5 Hz to 20 MHz | |||
* With A6302XL: 0.5 Hz to 17 MHz | |||
* With P6021: 120 Hz to 20 MHz | |||
}} | |||
{{Spec | Current range | | |||
* With A6312/A6302/A6302XL: 20 mA/Div to 100 A/Div (20:1) / 1 A/Div to 1,000 A/Div (1000:1) | |||
* With TCP202: 200 mA/Div to 100 A/Div (20:1) / 10 A/Div to 1,000 A/Div (1000:1) | |||
* With P6021: 20 mA/Div to 20 A/Div (20:1) / 1 A/Div to 1,000 A/Div (1000:1) | |||
}} | |||
{{EndSpecs}} | |||
==Manuals== | |||
* [http://w140.com/tek_ct4.pdf Tektronix CT-4 Manual (PDF)] | * [http://w140.com/tek_ct4.pdf Tektronix CT-4 Manual (PDF)] | ||
<gallery> | <gallery> | ||
Tek ct-4.JPG | |||
</gallery> | </gallery> | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] |